HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW Bosch Rexroth Indramat
MPN: R911326609
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW is part of the HCS IndraDrive Controllers series and is designed as a BASIC control section type drive controller. It features a MultiEthernet communication interface and a PROFIBUS interface, with support for IndraDyn Hiperface and EnDat encoders. This model has a device peak current of 5 Amps, uses an internal air cooling method with an integrated blower, and meets an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW drive controller is manufactured by Bosch Rexroth Indramat and belongs to the HCS IndraDrive Controllers series. Within the HCS01 line, this version 1 unit integrates the power stage, control logic, and blower-assisted cooling in a 50 mm-wide IP20 housing. It accepts three-phase mains power and fieldbus commands, then supplies regulated current to an attached IndraDyn motor so machine axes can follow precise speed and torque references in automated handling, packaging, and general motion platforms.
The power input window spans 3 × AC 200…500 V ±10%, allowing the same unit to operate on a wide range of plant voltages without transformer adaptation. During acceleration or transient load events, it can deliver a device peak current of 5 A, which is the maximum inverter output during those conditions. Thermal energy from the IGBTs is removed by internal air cooling through an integrated blower, eliminating the need for external ducting. An IP20 rating limits installation to control cabinets but simplifies wiring access. Communication with higher-level PLCs is handled through MultiEthernet ports that support several real-time Ethernet variants without additional option cards.
A BASIC control section, identified by the code BASIC, provides the core positioning and parameter processing functions. Motor position data is accepted through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while real-time fieldbus commands can also arrive over PROFIBUS, allowing the unit to work with either legacy or Ethernet-based networks. The unit has no integrated safety interface, so external safety relays or controllers must handle STO or emergency-stop duties. For energy sharing, the power section is classified as infeeding and fed, allowing connection to a common DC bus.
Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW:
Q: What type of communication interface is included on the HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW controller?
A: The HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW supports MultiEthernet for its communication interface.
Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW cooled?
A: An integrated blower provides internal air cooling in this drive controller.
Q: What is the device peak current for the HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW?
A: This unit has a peak current rating of 5 A.
Q: What is the mains voltage range for the HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW?
A: The controller operates at a mains voltage of 3 x AC 200 to 500 V with a tolerance of plus or minus 10%.
Q: What is the IP rating of the HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW?
A: The HCS01.1E-W0005-A-03-B-ET-EC-PB-NN-NN-FW is rated at IP20 for protection against solid objects.