4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW Bosch Rexroth Indramat

MPN: R911378686

No Tariffs On US Orders
  • Rated 4.3 (57 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Current response time:
5 Minutes 22 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW is part of the HCS IndraDrive Controllers series and is a drive controller with a MultiEthernet communication interface. This device uses air cooling through an integrated blower, supports a device peak current of 5 Amps, and operates with a mains voltage of 3 x AC 200 to 500 Volts. It has an IP20 rating and features an encoder interface for IndraDyn Hiperface and EnDat 2.1 or 2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat manufactures the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW, a member of the HCS IndraDrive Controllers series. This drive controller converts incoming three-phase power into a regulated DC link and modulated output for connected servo or induction motors. Acting as the closed-loop interface between motion commands and machine axes, it performs current, speed, and position regulation while exchanging status data with the plant network for precise, repeatable movement in automated production cells. Its role is to translate supply power and control commands into motor behavior that follows the requested motion profile under changing load conditions.

In operation, the device communicates with higher-level PLCs through the MultiEthernet port, so one hardware platform can be integrated with PROFINET, EtherNet/IP, or SERCOS networks without option cards. Protection is limited to IP20, which means the electronics should be installed inside a cabinet away from dust and dripping fluids. Thermal management relies on internal air cooling from an integrated blower, which removes heat without requiring an external heat sink. The power stage accepts 3-phase AC 200–500 V ±10% and can deliver a peak current of 5 A during short acceleration or deceleration events.

The fitted control section is the BASIC variant, which suits standard single-axis tasks and corresponds to design type B. Feedback wiring connects to the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, while the second encoder socket is left unpopulated when dual feedback is not needed. DC-link energy is handled by the Infeeding / Feeded power unit, which allows regenerated energy to be shared with adjacent drives. Firmware ordered separately is required, so the software can be selected for the intended application.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0005A03BETECNNS5NNFW
  • HCS01 1E W0005 A 03 B ET EC NN S5 NN FW
  • hcs01.1e-w0003-a-02-e-s3-ec-ep-l3-nn-fw
  • HCS1.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW controller support?

A: This model uses a MultiEthernet communication interface for flexible connectivity to various network protocols.

Q: Which encoder feedback interfaces are available on the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW?

A: The HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW supports encoder feedback via IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.

Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW drive controller cooled?

A: Cooling for this model is handled by an internal blower, utilizing air to manage heat within the controller.

Q: What is the IP rating for the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW drive controller?

A: This controller is rated at IP20, meaning it offers protection against solid objects larger than 12 mm but not against water entry.

Q: What is the peak current capability of the HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW?

A: The device supports a peak current of up to 5 A during operation.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-B-ET-EC-NN-S5-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and IP20 protection make the unit a strong fit for enclosed industrial drive systems. A 5 A peak current and 3 x AC 200...500 V ±10% mains range give this controller solid application flexibility.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo