4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW Bosch Rexroth Indramat

MPN: R911381868

No Tariffs On US Orders
  • Rated 4.5 (50 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW is a drive controller from the HCS IndraDrive Controllers series, designed with a BASIC control section and a peak current of 5 Amps. It features a MultiEthernet communication interface, operates at mains voltages of 3 x AC 200 to 500 V, and uses internal air cooling with an integrated blower. The controller has an IP20 rating and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW is a compact drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Installed inside an automation cabinet, the unit converts three-phase mains power into regulated output pulses that command servo or spindle motors, allowing precise torque, speed, and position control across coordinated machine axes. As an inverter module, it works with a modular control section, fieldbus networks, and external safety hardware to support closed-loop control in packaging lines, material-handling systems, and small machine tools.

The onboard network port supports MultiEthernet, allowing connection to EtherNet/IP, PROFINET, or EtherCAT without extra option cards. Its control section uses the BASIC design type, which provides standard PLC motion functions without higher-level safety extensions. Thermal energy is removed by internal air cooling through an integrated blower, and the blower moves cabinet air through the heat sink without external ducting. The power stage accepts 3 x AC 200 to 500 V ±10%, matching common industrial supply ranges. During acceleration or braking, it can deliver up to 5 A of peak current to the motor windings, which suits auxiliary and tooling axes. All live parts are housed behind an IP20 barrier, so the unit has finger-safe protection and still requires enclosure mounting for protection from dust and fluids.

Feedback is handled through a single encoder slot that recognizes IndraDyn Hiperface or EnDat 2.1/2.2 encoder signals, allowing the controller to close accurate position loops without add-on converters. The DC link arrangement supports infeeding and fed operation, which allows energy sharing and regeneration when several drives operate on the same bus. Within the HCS01 line, the controller uses design version 1, which keeps wiring patterns consistent, and the secondary communication bay is left unequipped so later expansion remains possible.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0005A03BETECNNS4NNPW
  • HCS01 1E W0005 A 03 B ET EC NN S4 NN PW
  • hcs01.1e-w0003-a-02-b-et-ec-pb-s4-nn-fw
  • HCS1.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW

Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW:

Q: What type of communication interface is available on the HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW controller?

A: The HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW supports MultiEthernet as its communication interface.

Q: What is the cooling method implemented in the HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW?

A: This drive controller uses air cooling provided by an integrated blower for internal temperature management.

Q: What encoder interface is included on the HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW?

A: The device supports encoder feedback with IndraDyn Hiperface and EnDat 2.1/2.2 via its primary interface.

Q: What is the peak current rating for the HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW controller?

A: The HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW has a device peak current of 5 A.

Q: What mains voltage range is supported by the HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW?

A: This controller operates with a mains voltage supply of 3 x AC 200...500 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-B-ET-EC-NN-S4-NN-PW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection support dependable cabinet integration in standard industrial environments. A 5 A peak current rating and 3 x AC 200...500 V input make the controller a strong fit for compact IndraDrive motion applications.’’