HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW Bosch Rexroth Indramat

MPN: R911333486

No Tariffs On US Orders
  • Rated 4.6 (34 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Current response time:
4 Minutes 52 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This HCS drive controller offers a device peak current of 5 Amps, an IP20 protection rating, and integrated air cooling through an internal blower. It supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and includes STO and SBC safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW is an HCS drive controller manufactured by Bosch Rexroth Indramat and placed within the HCS IndraDrive Controllers series. The device provides the link between plant mains and a single servo or induction motor, converting digital motion commands into regulated three-phase output for precise speed and torque control. Typical applications include automated packaging lines, material-handling stations, and compact printing modules where space-saving axis inverters are required.

Inside the HCS01 frame, communication with higher-level PLCs is handled through a MultiEthernet port that supports EtherNet/IP, PROFINET, and EtherCAT without additional hardware. The power stage accepts 3 × AC 200–500 V ±10% and can supply up to 5 A of peak current to the connected motor. Thermal losses are removed by internal air cooling, which uses an integrated blower and eliminates cabinet ducting. Rotor position and speed feedback are processed through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface; a second feedback channel is not included, which simplifies wiring. This unit is shipped as design version 1, and its firmware must be ordered as a separate sub-position so the software can match specific application requirements.

Axis control is executed by a basic control section that pairs mechanically and electrically with the power module. For cabinet mounting, the housing carries an IP20 rating, providing finger-safe protection but requiring installation in a closed enclosure to guard against dust and liquids. Integrated functional safety offers STO and SBC, allowing torque shutdown and brake release through the built-in terminals without external relays. Energy is exchanged over a common DC-bus link, letting multiple drives share a common supply and reducing line-side components and wiring.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0005A03BETECNNL4AAFW
  • HCS01 1E W0005 A 03 B ET EC NN L4 AA FW
  • hcs01.1e-w0003-a-02-b-et-ec-nn-l4-nn-fw
  • HCS1.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW:

Q: What type of communication interface does the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW support?

A: This model features MultiEthernet communication interface for flexible connectivity with various industrial control networks.

Q: What is the device peak current for the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?

A: The peak current output of this controller is 5 A, enabling reliable performance in its operational range.

Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW drive controller cooled?

A: Cooling is achieved through an integrated internal blower system that circulates air within the unit.

Q: What is the IP rating of the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?

A: It is rated at IP20, indicating protection against solid objects greater than 12 mm but not against water ingress.

Q: Which safety features are present on the HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW?.

A: The safety interface includes both STO (Safe Torque Off) and SBC (Safe Brake Control) functions.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW is an HCS drive controller with MultiEthernet communication, a very practical combination for modern automation networks. Internal air cooling and 5 A peak current support efficient thermal management and stable motion performance. STO and SBC safety functions make the BASIC control section an excellent choice for dependable drive control.’’