HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW Bosch Rexroth Indramat
MPN: R911331599
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features MultiEthernet communication and provides a device peak current of 5 Amps. It uses internal air cooling through an integrated blower and is rated IP20 for protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW is a drive controller engineered by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It coordinates power conversion and motion commands between an IndraDrive supply module and compatible servo or induction motors in automated machinery. Installed inside a control cabinet, the unit processes network data, generates switching pulses for the power section, and executes torque or speed loops that keep conveyor, packaging, and handling axes on profile during production cycles. Its role is centered on single-axis motor control where stable response and consistent communication with the higher-level controller are required.
A communication layer based on MultiEthernet links the controller directly to EtherNet/IP, PROFINET, and EtherCAT PLCs without external gateways. The power stage accepts a three-phase input of 3 x AC 200...500 V ±10%, covering common plant voltages, and it delivers up to 5 A peak current during acceleration or short positioning events. Thermal management relies on internal air cooling through an integrated blower, so heat is removed within the cabinet layout without the need for a separate ducted cooling path. The mounted control section is classified as BASIC, which suits standard single-axis tasks with a streamlined parameter range. It belongs to line series HCS01 and is produced as design version 1.
Machine-level safety is handled through the integrated STO (Safe Torque Off) and SBC (Safe Brake Control) interface, enabling immediate torque suppression and brake actuation through hardwired channels. Two identical feedback ports process IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback to capture position and speed data for closed-loop operation. DC power is supplied through infeeding and feed-through capability, which allows either standalone use or energy sharing on a common bus. The enclosure is rated IP20, so the controller is intended for protected cabinet installation while keeping its terminals accessible for wiring and service access.
Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW:
Q: Which communication protocols are supported by the HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW drive controller?
A: The HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW supports MultiEthernet communication, enabling integration with various network protocols.
Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW cooled?
A: This controller features an internal air cooling method using an integrated blower.
Q: What types of encoder interfaces does the HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW offer?
A: The device is equipped with two encoder interfaces that support IndraDyn Hiperface and EnDat 2.1/2.2.
Q: What level of ingress protection does the HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW offer?
A: The IP20 rating on this model provides protection against solid objects greater than 12.5 mm but not against water ingress.
Q: What is the peak current capacity of the HCS01.1E-W0005-A-03-B-ET-EC-EC-L4-NN-FW?
A: This drive controller has a device peak current of 5 A for handling load demands.