HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911334775
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a MultiEthernet communication interface. This HCS Drive Controller offers a device peak current of 5 Amps, an internal air cooling method with an integrated blower, and supports a mains voltage range of 3-phase AC 200 to 500 V. It includes encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and has a CANopen interface with IP20 protection.
Internal Product Review
The HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW is an HCS drive controller that stands out for dependable motion control and MultiEthernet communication. Internal air cooling through the integrated blower and a 5 A peak current support stable operation in demanding automation service. IP20 protection makes this controller a strong choice for clean industrial installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-B-ET-EC-CN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It serves as the power section of an axis by converting three-phase mains energy into regulated motor current, allowing automated equipment to follow precise speed and position commands. The unit belongs to the HCS01 line and pairs mechanically with a removable control section, so the control architecture can be matched to the needs of the motion channel.
The power stage accepts 3 × AC 200…500 V ±10% input and delivers a peak output of 5 A, which suits low-power servo or spindle motors during brief acceleration demand. Its IP20 enclosure requires installation inside a closed cabinet to prevent contact with energized parts. Heat is removed by internal air cooling from an integrated blower, which supports thermal management within the compact housing. The paired control section is the BASIC type noted for this configuration, and the controller is identified as design version 1. No additional design features are listed, and any safe torque off or other safe motion functions must be provided by external hardware because a safety interface is not equipped.
Field integration is provided through a MultiEthernet port that supports common real-time Ethernet protocols, along with a dedicated CANopen bus for distributed I/O or compatibility with existing network layouts. Motor feedback is handled through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, which allows the controller to process absolute position data from Rexroth and third-party encoder systems. DC bus behavior follows the infeeding and fed operation concept, so the inverter can receive energy from a shared supply or operate as the rectifier module when additional axes are connected.