HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW Bosch Rexroth Indramat
MPN: R911386816
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW is a drive controller in the HCS IndraDrive Controllers series featuring a MultiEthernet communication interface and an IP20 rating. It operates with a peak current of 5 amps, supports a mains voltage of 3 x AC 200 to 500 volts, and uses internal air cooling with an integrated blower. The controller includes IndraDyn Hiperface or EnDat encoder interfaces and offers STO and SBC safety functions.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW is an HCS Drive Controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series and belongs to the HCS01 line. The unit converts three-phase plant power into controlled motor current, enabling precise position, velocity, and torque loops in automated equipment. By pairing with machine PLCs over a fieldbus, it directs conveyors, pick-and-place stations, and packaging axes that require consistent electronic torque regulation. It is intended for compact single-axis installations where coordinated motion and predictable current control are required.
The controller accepts three-phase input of 3 x AC 200...500 V ±10%, allowing deployment on low- and medium-voltage networks without tap changers. Inside, an integrated blower provides internal air cooling that moves heat through the housing and removes the need for external ductwork. Output-stage peak capability is 5 A, giving short-term headroom for acceleration before the continuous current limit becomes active. Protection is rated IP20, so the terminals are finger-safe but the unit still requires cabinet installation. For networked control, the power section includes Multi-Ethernet, which supports protocol layers such as EtherNet/IP and PROFINET. This gives the controller flexibility when it is integrated into mixed-network automation systems. The second interface slot is not equipped.
A dual-channel safety module provides STO (Safe Torque Off) and SBC (Safe Brake Control), so the drive can remove torque and control a brake without external relays. Motor position data enters through encoder terminals for IndraDyn Hiperface/EnDat 2.1/2.2, enabling high-resolution feedback for closed-loop operation and stable correction during load changes. The power stage uses an infeeding and fed topology to return regenerative energy to a shared DC bus. That arrangement supports shared energy management when several axes operate on the same bus. The unit is design version 1 and pairs with a BASIC control section.
Frequently Asked Questions about HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW drive controller?
A: This model provides a MultiEthernet communication interface for flexible connectivity options.
Q: How does the HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW drive controller manage cooling?
A: Cooling is managed by an integrated blower that provides internal air circulation.
Q: What is the peak current rating for the HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW?
A: The HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW has a peak current capacity of 5 A.
Q: What built-in safety features are present in the HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW controller?
A: The safety interface includes Safe Torque Off (STO) and Safe Brake Control (SBC) features.
Q: What is the supported mains voltage input for the HCS01.1E-W0005-A-03-A-ET-EC-NN-L4-NN-FW?
A: This drive controller operates with a mains voltage range of 3 x AC 200 to 500 V with a tolerance of ±10%.