HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW Bosch Rexroth Indramat
MPN: R911370439
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW is part of the HCS IndraDrive Controllers series and is an ADVANCED design HCS drive controller. It features SERCOS III master communication, PROFIBUS, and encoder interfaces IndraDyn Hiperface and EnDat 2.1/2.2. The controller supports 3-phase AC mains voltages from 200 to 500 V, uses an integrated blower for cooling, and has a device peak current of 5 Amps with IP20 protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW drive controller is manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It regulates electrical power delivered to a connected servo or induction motor, executes motion commands, and exchanges status data with upper-level automation equipment. By combining power semiconductors with a detachable control section, the device forms a modular axis platform that fits compactly into machine control cabinets and supports synchronized multi-axis operation. Typical applications include pick-and-place gantries, forming presses, and conveyor drives where precise electronic gearing and stable speed control are required.
Internally, the power stage is rated for a device peak current of 5 A, allowing it to handle short acceleration bursts without saturation. Thermal energy is removed by internal air cooling, which uses an integrated blower to move cabinet air across the heat sink and avoids the need for external ducting. The supply terminals accept three-phase mains from 3 x AC 200...500 V ±10%, so the unit can operate on both 230 V and 480 V plant grids. Axis coordination is handled over a SERCOS III master cross-communication channel, and the control section is identified as ADVANCED. Component ingress protection is limited to IP20, so the housing is finger-safe and must be installed inside a sealed electrical enclosure.
The encoder feedback channel supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, enabling absolute position monitoring without external converters. Fieldbus integration with legacy controls is possible through PROFIBUS, which carries diagnostic and parameter data alongside the real-time motion network. The hardware belongs to the HCS01 line, and the power section can return excess braking energy to the DC link during deceleration. This arrangement keeps feedback handling and network communication within the same drive platform for coordinated axis control.
Frequently Asked Questions about HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW controller?
A: The HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW supports SERCOS III master communication with cross communication capability.
Q: What cooling method does the HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW utilize?
A: This drive controller uses an internal air cooling system with an integrated blower.
Q: What is the peak current rating for the HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW drive controller?
A: The HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW offers a device peak current of 5 amps.
Q: Which encoder types are supported by the primary interface of the HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW?
A: This unit is equipped with encoder support for IndraDyn Hiperface and EnDat 2.1/2.2 on its first interface.
Q: What mains voltage range is required for the HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW controller?
A: The HCS01.1E-W0005-A-03-A-CC-EC-PB-S4-NN-FW operates on a three-phase AC mains voltage range of 200 to 500 volts, plus or minus 10 percent.