HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW Bosch Rexroth Indramat
MPN: R911370438
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a SERCOS III master communication interface and uses air cooling with an integrated blower. It supports a peak current of 5 Amps and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW is a drive controller produced within the HCS IndraDrive Controllers series. As a compact inverter module, it controls synchronous and asynchronous motors in automated machining cells, packaging lines, and material-handling axes, delivering speed and torque commands from the motion control layer. The unit serves as the link between PLC motion programs and connected motors, so it can support coordinated axis behavior in decentralized automation layouts. That role lets the drive translate control commands into regulated electrical output for positioning, speed control, and general axis motion. It belongs to the HCS01 line and is intended for cabinet-based installation rather than stand-alone field mounting.
The controller exchanges real-time motion data through a SERCOS III master with cross communication interface, allowing deterministic network cycles for multi-axis coordination. It accepts a line input of 3 x AC 200 to 500 V ±10%, which gives the drive flexibility across common industrial power systems. Heat is removed by internal air cooling through an integrated blower, so no external ducting is required for normal cabinet installation. During acceleration, the inverter can supply up to 5 A of peak current to the motor windings, and the housing is rated to IP20 for installation in a protected enclosure.
The control section is classified as ADVANCED, and the unit is design version 1. Motor feedback is connected through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, while the second feedback interface is not equipped. The power supply arrangement supports infeeding or fed operation, permitting the drive to supply energy to or draw energy from a common DC bus. This arrangement suits shared DC-bus systems in which braking energy from one axis can be used by another axis instead of being handled locally. It also supports installations where several coordinated drives exchange power during changing load conditions.
Frequently Asked Questions about HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW:
Q: What type of communication interface does the HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW controller use?
A: The HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW supports SERCOS III master communication with cross communication capabilities.
Q: What is the cooling method used for the HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW drive controller?
A: This model uses air cooling provided by an integrated internal blower.
Q: What is the peak current capability of the HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW?
A: The device has a peak current rating of 5 A.
Q: What level of ingress protection (IP rating) does the HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW provide?
A: The controller features an IP20 rating, meaning it is protected against solid objects larger than 12.5 mm but not against water.
Q: What mains voltage range does the HCS01.1E-W0005-A-03-A-CC-EC-NN-S4-NN-FW require for operation?
A: The controller operates with a mains voltage of 3 x AC 200 to 500 V with a ±10% tolerance.