HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW Bosch Rexroth Indramat
MPN: R911338315
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It supports a peak current of 5 Amps and uses an internal air cooling method with an integrated blower. This controller features SERCOS III master cross communication and MultiEthernet interfaces, and operates with an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It belongs to the HCS01 line, uses design version 1, and includes the ADVANCED control section assigned to this model. The unit directs power and motion commands to individual axes in automated cells, making it suitable for compact installations where cabinet space must be used efficiently. It does not include an integrated safety interface, so any required safety functions must be handled by external equipment.
The controller accepts a three-phase mains supply of 3 x AC 200 to 500 V ±10%, allowing direct connection to many industrial power systems. During acceleration, it can deliver a peak current of 5 A, which suits small servo axes and other compact motion applications. The IP20 enclosure helps protect against accidental contact and requires installation inside an enclosed control cabinet. Heat is removed by internal air cooling through an integrated blower, and the fan moves cabinet air across the heat sink without requiring external ducting. Motion data and synchronization telegrams are exchanged through a SERCOS III master with cross communication interface for deterministic timing in multi-axis operation.
Feedback is connected at the X4 terminal and supports IndraDyn Hiperface or EnDat 2.1/2.2 encoder feedback, allowing absolute position values to reach the drive without additional adapters. Network integration on X2 is handled by the MultiEthernet port for industrial Ethernet communication with higher-level control systems. High-level functions such as electronic camming are processed internally, so extra motion hardware is not required for those tasks. The power architecture also supports DC-bus energy exchange between connected converters, which allows shared bus operation in systems that use multiple drives.
Frequently Asked Questions about HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW drive controller?
A: The HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW supports SERCOS III master communication with cross communication capability.
Q: What is the maximum device peak current for the HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW?
A: This drive controller operates with a device peak current of 5 A.
Q: What cooling method does the HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW use?
A: Cooling is achieved by an internal air method using an integrated blower.
Q: What mains voltage range is supported by the HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW?
A: The drive controller operates with a mains voltage range of 3 x AC 200 to 500 V ±10%.
Q: What is the IP rating of the HCS01.1E-W0005-A-03-A-CC-EC-ET-NN-NN-FW?
A: The protection rating for this drive controller is IP20.