4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW Bosch Rexroth Indramat

MPN: R911369749

No Tariffs On US Orders
  • Rated 4.4 (56 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface, a 5 Amp device peak current, and is designed for 3 phase AC mains voltage from 200 to 500 Volts. The unit uses air cooling with an integrated blower and has an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW is an HCS IndraDrive controller from the HCS01 line. As a compact axis inverter, it regulates power flow between a three-phase supply and compatible synchronous or asynchronous motors used in automated machinery. Within an automation cell, the unit executes torque, speed, and position control loops so the higher-level system can coordinate motion with precise timing. Its compact format suits installations where axis control must be integrated into a cabinet without adding unnecessary bulk.

It accepts a three-phase input supply rated at 3 x AC 200...500 V ±10% and can deliver up to 5 A of peak current to the motor phases. The control section is identified as ADVANCED, indicating the control configuration used in this model. Internal thermal management uses internal air cooling through an integrated blower, so heat is removed inside the unit without requiring a separate external fan assembly. Communication is handled through a SERCOS III master interface with cross communication, which supports deterministic data exchange and coordination between drives on the network. The rectifier stage can operate from an individual DC link or from a shared DC bus, which supports flexible power architecture in multi-axis systems.

Feedback processing uses an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface on Interface 1 for absolute position signals and encoder emulation on Interface 2 for compatibility with legacy control chains. The enclosure has a protection rating of IP20, so the unit is intended for installation inside a control cabinet rather than direct exposure on the machine. Power exchange with the DC bus supports infeeding or fed operation, allowing the controller to work either as a standalone supply participant or within an energy-sharing drive group. A dedicated safety interface is not included, so any required safety functions must be provided by external system components.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0005A03ACCECEMNNNNFW
  • HCS01 1E W0005 A 03 A CC EC EM NN NN FW
  • hcs01.1e-w0003-a-02-a-cc-ec-da-nn-nn-fw
  • HCS1.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW:

Q: What communication interface is supported by the HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW?

A: This drive controller uses SERCOS III master communication with cross communication capabilities.

Q: How is the HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW features internal air cooling provided by an integrated blower.

Q: What type of encoder interfaces are provided on the HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW?

A: This unit supports encoder connections via IndraDyn Hiperface or EnDat 2.1/2.2 through its primary interface.

Q: What is the mains voltage range for the HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW?

A: The HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW is rated for 3-phase AC supply between 200 and 500 V, with a tolerance of ±10%.

Q: What is the peak current rating for the HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW drive controller?

A: This model achieves a peak device current of 5 A during operation.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-A-CC-EC-EM-NN-NN-FW is an HCS drive controller well suited for precise motion control, featuring SERCOS III master cross communication and an ADVANCED control section. Internal blower air cooling and IP20 protection support stable cabinet integration in industrial automation systems. A 3 x AC 200 to 500 V mains range with 5 A peak current makes the unit a strong choice for compact servo applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo