4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW Bosch Rexroth Indramat

MPN: R911345866

No Tariffs On US Orders
  • Rated 4.6 (59 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface and has an ADVANCED control section design. The device has a peak current of 5 Amps and supports air cooling through an integrated blower, with an IP20 rating and a mains voltage range of 3 x AC 200 to 500 Volts plus or minus 10 percent.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It regulates power flow to servo and induction motors in automated machinery, supporting controlled acceleration, speed regulation, and motion-related diagnostics in one compact unit. The controller has an IP20 enclosure rating, so it is intended for installation inside electrical panels where limited ingress protection is sufficient and where the surrounding cabinet provides the external protective barrier.

The power section accepts a three-phase supply of 3 x AC 200…500 V ±10% and can deliver up to 5 A of peak current to the connected motor windings. Internal thermal management uses internal air cooling through an integrated blower, so no external ducting is required when the unit is mounted in a cabinet and heat can be carried away within the enclosure airflow path. The device belongs to design version 1 of the HCS01 line. It also uses an infeeding/feeded power supply concept, allowing multiple drives on the same DC bus to share returned energy during normal machine operation.

Application-layer integration is handled through SERCOS III master with cross communication, enabling deterministic network traffic among drives and PLCs and allowing coordinated data exchange across the motion system. The primary feedback port uses IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback, while the secondary port provides encoder emulation for legacy control loops that still require a conventional feedback signal. The control section is the ADVANCED type, which supports extended motion functions within the matched power configuration. Functional safety is implemented through STO (Safe Torque Off), allowing torque-free shutdown without external contactors.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0005A03ACCECEML3NNFW
  • HCS01 1E W0005 A 03 A CC EC EM L3 NN FW
  • hcs01.1e-w0003-a-02-a-cc-ec-cn-s4-nn-fw
  • HCS1.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW:

Q: What type of communication interface is supported by the HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW drive controller?

A: The HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW offers a SERCOS III master communication interface with cross communication capabilities.

Q: What is the control section design type of the HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW?

A: This controller uses an ADVANCED control section design type, offering enhanced control features.

Q: How is the HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW cooled?

A: Integrated internal air cooling with a built-in blower is used in this model.

Q: What is the mains voltage requirement for the HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW?

A: This drive controller operates at a mains voltage of 3 x AC 200...500 V with a tolerance of ±10%.

Q: What type of safety interface does the HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW provide?

A: A Safe Torque Off (STO) safety interface is included for safe motor shutdown.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-A-CC-EC-EM-L3-NN-FW is an HCS Drive Controller with an ADVANCED control section and internal air cooling. SERCOS III master cross communication and encoder support for IndraDyn Hiperface or EnDat 2.1/2.2 make integration and feedback handling especially capable in motion systems. IP20 protection and STO Safe Torque Off add practical cabinet suitability and a strong safety profile.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo