HCS01.1E-W0005-A-03-A-CC-EC-EC-NN-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911336676
Ask for AvailabilityThe Bosch Rexroth Indramat HCS01.1E-W0005-A-03-A-CC-EC-EC-NN-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features an ADVANCED control section design and supports SERCOS III master communication. The unit operates with a device peak current of 5 Amps, an IP20 protection rating, and uses an internal air cooling blower.
Internal Product Review
The HCS01.1E-W0005-A-03-A-CC-EC-EC-NN-NN-FW is an HCS Drive Controller featuring SERCOS III master communication and an ADVANCED control section. Internal air cooling through an integrated blower supports stable thermal management, and IP20 protection suits enclosed industrial cabinets well. A 3 x AC 200...500 V ±10% mains range makes this Bosch Rexroth Indramat controller a strong fit for flexible drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-A-CC-EC-EC-NN-NN-FW belongs to the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. This drive controller forms the power stage between a higher-level PLC and servo or spindle motors, translating setpoints into regulated current and voltage so motion axes follow commanded profiles in automated machinery. The unit follows line code HCS01 and is classified as design version 1. Its compact format suits protected control cabinets where centralized drive regulation is required.
For networked motion systems, the controller offers a SERCOS III master with cross communication interface, allowing deterministic exchange of real-time process data among drives. Its control electronics use the ADVANCED design type, which expands internal processing for multi-axis coordination and deeper diagnostics. The power stage accepts 3 x AC 200–500 V ±10% mains and can deliver up to 5 A of peak output current to matched IndraDyn motors. An IP20 protection level means fingers and solid objects over 12 mm are excluded while ventilation openings remain accessible, so the device must be mounted inside an enclosure with controlled ambient conditions.
Thermal stability is maintained by internal air cooling through an integrated blower, and the blower moves cabinet air across the heat sinks without requiring external ducting. Position feedback is handled on both Interface 1 and Interface 2 through a shared IndraDyn Hiperface/EnDat 2.1/2.2 encoder channel, which simplifies cable layouts when dual-loop feedback is needed. The power section supports infeeding/fed operation, so it can absorb regenerated energy from decelerating axes and return it to the DC bus. The controller is not equipped with a safety fieldbus, so machine-level safety must be handled through separate devices.