4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911337825

No Tariffs On US Orders
  • Rated 4.5 (37 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW is part of the HCS IndraDrive Controllers series and is an HCS drive controller with an internal air cooling method. It features a SERCOS III communication interface, supports a device peak current of 3 A, and has an encoder interface for IndraDyn Hiperface or EnDat 2.1/2.2. The controller comes with IP20 protection and a safety interface for Safe Torque Off.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW is a drive controller built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It directs low-power servo axes in industrial automation by issuing current, speed, and position commands to connected motors. Power electronics, fieldbus communication, and control logic share one enclosure, which helps reduce cabinet space and simplifies integration in compact systems. In operation, the controller regulates motor response so axes can follow commanded motion profiles during indexing, positioning, and speed-controlled tasks. It is suited for packaging equipment, material-handling units, and laboratory machines that require precise motion from a small control platform.

This model communicates through SERCOS III, enabling deterministic real-time exchange with PLCs and neighboring drives. A peak phase capacity of 3 A supports short acceleration demands on compatible motors without oversizing the control hardware. The power stage accepts a three-phase feed of 110–230 V AC with a tolerance of ±10%, matching common factory mains. Heat is removed by internal air cooling with an integrated blower, so no external cooling fan is required. Because the enclosure is rated IP20, the unit must be installed inside a cabinet. Its power topology also allows energy to be drawn from and returned to a shared DC bus during regenerative operation.

The control section is the ECONOMY variant, and it is released as design version 1. A multifunction feedback socket supports IndraDyn Hiperface/EnDat 2.1/2.2 encoders, while a second feedback channel is omitted to keep the unit compact. This arrangement is suitable for single-motor applications that do not require an additional feedback input. Integrated safe torque shutoff is provided by the STO interface, which removes motor torque when a safety input is asserted. The feature set fits pick-and-place arms, indexers, and small conveyors that need precise motion control in a compact drive package.

Communication Interface
SERCOS III
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0003A02ES3ECNNL3NNFW
  • HCS01 1E W0003 A 02 E S3 EC NN L3 NN FW
  • hcs04.2e-w0910-n-06-nnnn
  • HCS1.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW:

Q: What communication protocol does the HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW drive controller use?

A: This model supports the SERCOS III communication interface for networking and control.

Q: What cooling method is utilized by the HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW controller?

A: The HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW uses an integrated blower for internal air cooling.

Q: What is the maximum device peak current of the HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW?

A: The peak current rating for this drive controller is 3 A.

Q: What safety interface is present on the HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW?

A: This controller includes an STO (Safe Torque Off) safety interface.

Q: What mains voltage range does the HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW support?

A: The HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW is rated for mains voltages from 3 x AC 110 to 230 V with a 10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-E-S3-EC-NN-L3-NN-FW is a Bosch Rexroth Indramat HCS drive controller that stands out for SERCOS III communication and an ECONOMY control section. Support for 3 x AC 110...230 V mains input and STO Safe Torque Off makes the controller a strong choice for compact, safety-conscious drive systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo