HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW Bosch Rexroth Indramat
MPN: R911346413
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features MultiEthernet and PROFIBUS communication interfaces and is rated for a device peak current of 3 Amps. It uses internal air cooling through an integrated blower and holds an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW is a drive controller power section produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It forms the power interface between facility mains and servo motors, providing controlled current and serving as the platform for the matching control section. Within automated cells, the device supplies regulated energy, executes axis commands, and supports real-time feedback, allowing precise speed, torque, and positioning functions across conveyors, pick-and-place stations, and a wide range of processing equipment.
This power section accepts a three-phase supply of 110 to 230 V ±10%, enabling deployment on low-voltage industrial grids. Internally, it converts that input into pulse-width-modulated outputs while sustaining a device peak current of 3 A for brief acceleration demands. The enclosure has IP20 protection, so the unit must be mounted inside a cabinet. Heat from the IGBT bridge is expelled by internal air cooling through an integrated blower, eliminating the need for external ducting. Command and diagnostic data reach the drive through the MultiEthernet port, which supports several real-time Ethernet protocols without option cards.
The matching control electronics mount directly on top and use the BASIC design type, in line with the pairing code. Feedback connects through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, allowing absolute position evaluation without adapters. For legacy PLC networks, cyclic data exchange is available over PROFIBUS, giving deterministic control alongside Ethernet. Energy flows through an infeeding and fed power topology, allowing the module to absorb regenerated energy or share a common DC bus with other HCS units. Design Version 1 remains compatible with first-generation HCS01 accessories.
Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW:
Q: What cooling method is used in the HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW drive controller?
A: The HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW utilizes an internal air cooling method with an integrated blower.
Q: What type of communication interface does the HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW support?
A: This model features MultiEthernet communication for flexible network integration.
Q: What is the device peak current of the HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW?
A: It supports a peak current of 3 A for demanding applications requiring short bursts of higher power.
Q: What is the IP rating of the HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW?
A: The drive controller has an IP20 rating, meaning it is protected against solid objects greater than 12.5 mm but not against water.
Q: What is the mains voltage range for the HCS01.1E-W0003-A-02-B-ET-EC-PB-S4-NN-FW drive controller?
A: This controller operates on a mains voltage range of 3 x AC 110 to 230 V with a tolerance of plus or minus ten percent.