The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW is part of the HCS IndraDrive Controllers series and is a HCS drive controller with a peak current of 3 Amps. It features a MultiEthernet communication interface, supports encoder connections such as IndraDyn Hiperface and EnDat 2.1/2.2, and uses internal air cooling through an integrated blower. The device operates with a mains voltage of 3 x AC 110 to 230 V and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW is a drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It conditions mains power and command data for low-power servo or spindle axes, allowing speed and torque regulation in conveyors, pick-and-place stations, and compact assembly cells. A combined power and control section helps reduce cabinet space while supplying fieldbus links and encoder evaluation required for closed-loop motion. This arrangement also supports compact machine layouts where the drive, motor feedback, and network connection must fit within a limited enclosure.
It operates from a three-phase supply of 3 x AC 110–230 V ±10%, which supports machines supplied by regional power systems or isolation transformers. The inverter can source up to 3 A of peak current, giving the motor short-term current for acceleration and transient load changes. Communication is handled through MultiEthernet, and its single RJ45 port can switch among EtherNet/IP, PROFINET, EtherCAT, and SERCOS III protocols. This allows one hardware platform to work with different real-time Ethernet control environments. Rotor position is received through the feedback connector that supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2, and the IP20 housing provides finger protection inside a properly enclosed cabinet.
The controller is supplied with a BASIC control section, so it is set up for standard motion functions rather than expanded control features. Its power module is an infeeding / fed type, which allows regenerated energy to return to the DC bus or accept power from an upstream supply during multi-axis operation. Thermal removal is achieved by internal air cooling through an integrated blower, and unobstructed cabinet airflow helps the unit dissipate heat during continuous use. The mechanical footprint follows the HCS01 line size and matches Design Version 1. The second communication slot is empty.
Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW:
Q: How is the HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW drive controller cooled?
A: This model features an internal air cooling method using an integrated blower.
Q: What communication interface does the HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW support?
A: The drive controller supports MultiEthernet as its communication interface for flexible connectivity.
Q: What is the mains voltage range supported by the HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW?
A: The mains voltage required for operation is 3 x AC 110...230 V ±10%.
Q: What is the peak current capability of the HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW?
A: This drive controller has a device peak current rating of 3 A.
Q: What type of encoder interface is available on Interface 1 of this drive controller?
A: The HCS01.1E-W0003-A-02-B-ET-EC-NN-SB-NN-FW offers an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface as Interface 1.