4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911340075

No Tariffs On US Orders
  • Rated 4.6 (41 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships Fast

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW is part of the HCS IndraDrive Controllers series and is designed as a BASIC type HCS drive controller. It features MultiEthernet communication and an internal air cooling system with an integrated blower. The controller has a peak current of 3 Amps, supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and operates with a mains voltage of 3 x AC 110 to 230 V.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW is a compact AC drive controller from Bosch Rexroth Indramat in the HCS IndraDrive Controllers series. It regulates velocity, torque, and position for servo axes and small spindles in automated machinery. The controller routes power and feedback between the mains supply, the IndraDrive control section, and connected motors. This makes it suitable for compact machine axes that require coordinated motion and stable closed-loop control.

This controller operates from a three-phase supply of 3 × AC 110–230 V ±10%, allowing use on low-voltage factory networks without an isolation transformer. Its device peak output current is 3 A, so the unit is suited to fractional-kilowatt motors that need quick but moderate torque bursts. Thermal energy is removed by internal blower cooling, which avoids external ducting and helps keep cabinet layouts simple. Network traffic for setup and PLC commands passes through the built-in MultiEthernet port, allowing direct connection to EtherNet/IP, PROFINET, or SERCOS III networks. An IP20 housing protects live parts from accidental contact and from settled dust when the drive is mounted inside a control cabinet. Because the cabinet provides the outer enclosure protection, no additional gasketing is included on the drive itself.

The encoder feedback socket accepts Encoder IndraDyn Hiperface / EnDat 2.1 / 2.2 signals, giving the drive high-resolution position data from compatible motors. These feedback options let the controller work with several common encoder formats used in the IndraDrive platform. The control section uses a BASIC design for standard motion functions. The power stage supports a common DC bus, allowing regenerated energy to be shared with neighboring axes. The unit is design version 1, which sets the mechanical footprint and connector style used in the HCS01 line.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0003A02BETECNNS4NNFW
  • HCS01 1E W0003 A 02 B ET EC NN S4 NN FW
  • hcs04.2e-w0350-n-04-dnbn
  • HCS1.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW:

Q: What is the device peak current for the HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW drive controller?

A: The HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW controller operates with a peak current of 3 A.

Q: What type of communication interface does the HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW feature?

A: This drive controller is equipped with a MultiEthernet communication interface, allowing flexible network integration.

Q: What cooling method is used in the HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW controller?

A: Cooling for this model is handled internally through an integrated blower.

Q: What mains voltage is supported by the HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW controller?

A: The HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW supports a mains voltage of 3 x AC 110...230 V ±10%.

Q: What encoder feedback interface does the HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW provide?

A: An IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface is standard on this controller.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-B-ET-EC-NN-S4-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal air cooling through an integrated blower supports effective thermal management, while IP20 protection suits controlled cabinet installations. A 3 A peak current rating and 3 x AC 110 to 230 V mains input make the unit a strong fit for compact IndraDrive applications.’’