4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW Bosch Rexroth Indramat

MPN: R911408870

No Tariffs On US Orders
  • Rated 4.3 (37 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW is a drive controller in the HCS IndraDrive Controllers series. It features an IP20 protection rating, supports MultiEthernet communication, and has a device peak current of 3 Amps. The controller is cooled internally using an integrated blower and operates at 3 x AC 110 to 230 Volt mains voltage.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW belongs to the HCS01 line of HCS IndraDrive Controllers from Bosch Rexroth Indramat. This drive controller rectifies incoming three-phase power and modulates motor voltage in response to motion commands from the control system. It serves as the electrical link between a PLC and on-machine actuators, supporting coordinated position, speed, and stopping functions in packaging, handling, and assembly equipment. In this role, it conditions electrical power for the motor while translating higher-level commands into controlled axis behavior. Its compact format suits cabinet-mounted automation systems where multiple axes must be controlled from a common platform.

With a MultiEthernet port, the controller can communicate over common industrial networks without additional interface cards. Its supply range of 3 x AC 110...230 V ±10% fits both low and standard 230 V systems, and the DC bus can provide up to 3 A of peak current for moderate-torque axes. The enclosure carries an IP20 rating, so the unit is intended for installation inside a control cabinet where contact protection is required. Heat is removed by internal air cooling, which circulates cabinet air with an integrated blower and avoids external ductwork. This cooling method supports straightforward panel integration where external ventilation hardware is not desired.

The unit uses a BASIC control section in design version 1, providing core motion and safety functions for standard axis control. Position feedback is handled through the Encoder IndraDyn Hiperface/EnDat 2.1/2.2 connection, while a separate Encoder emulation channel returns synthesized signals for compatibility with legacy equipment. The feedback arrangement supports precise motor commutation and stable closed-loop axis response during normal machine cycles. Power can be shared over a common DC bus through an infeed/shared-bus arrangement, which allows several HCS01 modules to exchange energy during operation. This layout fits multi-axis systems that use coordinated motion and centralized cabinet installation.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0003A02BETECEMS4NNFW
  • HCS01 1E W0003 A 02 B ET EC EM S4 NN FW
  • hcs03.1e-w0350-a-05-nnnv
  • HCS1.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW controller offer?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW provides a MultiEthernet communication interface for flexible connectivity options.

Q: What is the device peak current for the HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW?

A: This drive controller has a peak current rating of 3 A, supporting efficient operation for small-to-medium loads.

Q: How is the HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW controller cooled?

A: The cooling method utilizes internal air through an integrated blower to maintain proper operating temperatures.

Q: Which encoder interfaces are supported on the HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW?

A: This model supports encoder compatibility with IndraDyn Hiperface, EnDat 2.1, and 2.2 interface standards.

Q: What level of protection does the IP20 rating offer for the HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW has an IP20 rating, meaning it provides basic protection against solid objects but is not protected against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-B-ET-EC-EM-S4-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection support dependable cabinet operation in standard industrial installations. A 3 x AC 110...230 V mains range paired with 3 A peak current makes the unit a well-matched choice for compact motion control duties.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo