4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW Bosch Rexroth Indramat

MPN: R911345404

No Tariffs On US Orders
  • Rated 4.6 (16 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller offers a device peak current of 3 Amps, supports MultiEthernet communication, and features STO safety interface. It is rated for IP20 protection and uses air cooling through an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW drive controller is part of the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. Intended for cabinet installation, it serves as the power and control core for IndraDyn servo axes in automated machinery. By regulating current and voltage to the motor, it handles fast motion tasks locally and supports positioning, speed control, and torque control in compact packaging, handling, and processing equipment. Because the control and power functions are combined in one unit, the drive can manage closed-loop axis behavior without requiring a separate motion module for the same axis.

This controller connects directly to plant mains rated at 3 x AC 110 to 230 V ±10% and can deliver up to 3 A of peak output to the motor windings. Cooling uses internal air circulation from an integrated blower, so heat is removed within the narrow HCS01 housing without external heat sinks. Network integration is handled through a MultiEthernet port that supports common industrial Ethernet protocols and allows the drive to exchange cyclic control data with higher-level automation systems. The electronics are protected to IP20, which is suitable for enclosed control cabinets where contact protection and organized cable routing are provided. It is a design version 1 unit in the HCS01 line and uses an infeeding and fed power supply arrangement.

The control section uses the BASIC design type, so the feature set remains focused on core axis control functions. Axis feedback enters through a first connector that accepts IndraDyn Hiperface/EnDat 2.1/2.2 encoder signals, while a second port provides an encoder emulation output for connected monitoring devices or legacy equipment. Drive enable monitoring is supported by the integrated STO (Safe Torque Off) circuit, which removes torque generation at the motor without requiring separate external contactors for a Category 0 stop. This arrangement lets the controller process feedback and handle safe shutdown functions within the same housing, which helps keep cabinet layout straightforward and keeps signal routing concentrated at the drive.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HCS011EW0003A02BETECEML3NNFW
  • HCS01 1E W0003 A 02 B ET EC EM L3 NN FW
  • hcs03.1e-w0350-a-05-nnbn
  • HCS1.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW?

A: This drive controller supports a MultiEthernet communication interface for flexible network integration.

Q: How is the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW drive controller cooled?

A: Cooling is achieved using an internal blower for air ventilation within the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW.

Q: What is the peak current specification for the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW?

A: The device is rated for a peak current of 3 A during operation.

Q: What type of safety interface does the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW offer?

A: This model features the STO (Safe Torque Off) safety interface for operational safety functions.

Q: What mains voltage range does the HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW support?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW operates on a mains voltage of 3 x AC 110 to 230 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-B-ET-EC-EM-L3-NN-FW is an HCS drive controller with a BASIC control section that feels well suited for streamlined machine control. MultiEthernet communication and encoder support for IndraDyn Hiperface or EnDat 2.1/2.2 give the unit strong integration flexibility in modern servo systems. Internal air cooling through an integrated blower supports stable thermal management, while STO safety adds valuable protection for demanding installations.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo