4.95 based on 202 reviews

🙶 First-time customer with Wake Industrial. The ordering process was completely seamless. The part that we o... 🙷

HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW Bosch Rexroth Indramat

MPN: R911340778

No Tariffs On US Orders
  • Rated 4.6 (39 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. This unit is rated for a peak device current of 3 Amps, has an IP20 protection rating, and uses air cooling with an internal blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It forms the power and feedback link between an AC supply and Rexroth IndraDyn motors, delivering closed-loop regulation for motion axes in automation systems such as pick-and-place modules, feeders, and packaging stations. Its role is to convert mains power into a precisely metered output while coordinating encoder feedback so commanded position, velocity, and torque targets are met in real time.

The power stage accepts a three-phase supply of 3 x AC 110–230 V with a tolerance of ±10%, allowing the unit to be wired directly to low-voltage plant mains without an isolation transformer. Internally, an integrated blower provides internal air cooling, so enclosure heat is removed without external ducting and panel layout stays simple. During rapid accelerations, the controller can deliver a peak output current of 3 A, which is the maximum short-term current available to a paired motor before current limiting begins. The protective housing is rated IP20, which indicates finger-safe terminals and suitability for installation inside a closed cabinet. Network connectivity is provided through MultiEthernet, enabling direct integration with EtherNet/IP, PROFINET, or EtherCAT topologies from a single hardware port.

The control section mounted on this power module is the BASIC design, so parameter access, safety functions, and processing capacity fit standard point-to-point motion tasks. Power is exchanged with the DC bus through an infeed/feed power concept, so the drive can either return braking energy to upstream units or receive energy from them in modular multi-axis systems. Position data are read through dual-channel IndraDyn Hiperface / EnDat 2.1 / 2.2 encoder inputs, which provide high-resolution feedback without additional option cards.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0003A02BETECECS4NNFW
  • HCS01 1E W0003 A 02 B ET EC EC S4 NN FW
  • hcs03.1e-w0350-a-05-lnbv
  • HCS1.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW drive controller?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW supports MultiEthernet communication for versatile industrial networking.

Q: What is the device peak current rating of the HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW?

A: This model operates with a device peak current of 3 A, suitable for low to moderate power applications.

Q: What type of cooling method does the HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW utilize?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW uses an internal air cooling system with an integrated blower.

Q: What is the IP rating of the HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW?

A: This drive controller features an IP20 rating, offering basic protection against solid objects greater than 12.5 mm.

Q: What mains voltage range does the HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW support?

A: The HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW operates on a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-B-ET-EC-EC-S4-NN-FW is an HCS drive controller with a BASIC control section and MultiEthernet communication. Internal blower cooling and IP20 protection support dependable cabinet integration in standard industrial installations. Dual encoder support for IndraDyn Hiperface or EnDat 2.1/2.2 is a standout advantage for precise motor feedback.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo