HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW Bosch Rexroth Indramat
MPN: R911334773
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW is part of the HCS IndraDrive Controllers series and is a BASIC design drive controller. It features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. The controller operates with a device peak current of 3 Amps, uses an internal air cooling method, and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW is a compact drive controller manufactured by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It regulates power to low-power servo axes in distributed automation cells. By combining power electronics and a control section in one housing, the unit handles speed, torque, and positioning tasks for conveyor segments, small handling modules, and auxiliary machine tools. This integrated layout helps reduce panel space while keeping motion control functions in a single device.
The power stage accepts a three-phase supply of 3 x AC 110–230 V ±10%, eliminating the need for an external step-down transformer. A device peak current of 3 A supports short acceleration or deceleration commands to connected motors. Thermal energy is removed by internal air cooling with an integrated blower, so cabinet airflow remains independent of the drive. The enclosure has an IP20 rating, which means it must be mounted in a protected control cabinet. For higher-level integration, the controller uses a MultiEthernet interface that supports EtherNet/IP, PROFINET, or Sercos III over the same port while maintaining real-time communication across connected axes.
The control section is the BASIC variant, which matches the type code and indicates that no additional option cards are installed. Motor feedback is processed through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder input for direct connection to compatible motor feedback systems, and auxiliary I/O or diagnostics can be exchanged through CANopen. DC-bus energy management uses an infeeding and fed topology, which supports common-bus operation and regenerative energy sharing among multiple axes. No safety interface is integrated, so applications that require functional safety need separate safety hardware.
Frequently Asked Questions about HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW:
Q: What communication interface options are available on the HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW drive controller?
A: The HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW supports MultiEthernet communication, allowing integration with multiple industrial Ethernet protocols.
Q: How is the HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW drive controller cooled?
A: Air, internal cooling is used through an integrated blower for managing the device's temperature.
Q: What is the peak current capability of the HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW?
A: This drive controller provides a device peak current of 3 A for demanding applications.
Q: What mains voltage does the HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW drive controller support?
A: A mains voltage of 3 x AC 110 to 230 V ±10% is required for operation of this controller.
Q: What is the IP rating of the HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW controller?
A: The HCS01.1E-W0003-A-02-B-ET-EC-CN-NN-NN-FW achieves IP20 protection, offering limited ingress protection against solid objects.