The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW is an HCS Drive Controller in the HCS IndraDrive Controllers series. It features a device peak current of 3 Amps and operates on a mains voltage of 3 x AC 110 to 230 V. The controller provides SERCOS III and PROFIBUS communication interfaces, and includes STO and SBC safety interfaces.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Bosch Rexroth Indramat manufactures the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW as part of the HCS IndraDrive Controllers series. This HCS drive controller coordinates power conversion and motion commands for compact servo axes in industrial automation lines, linking the mains supply to motor inverters while handling feedback and fieldbus data within a single enclosure. Its design version is 1 and the control section is classified as ADVANCED, so the internal processor can execute extended drive functions provided by IndraWorks engineering software.

The controller operates from a three-phase supply of 3 × AC 110 to 230 V ±10%, allowing installation on low-voltage plants without an external transformer. A peak output of 3 A permits short acceleration bursts for lighter servo motors, and the unit uses internal air cooling through an integrated blower, eliminating ductwork inside the cabinet. The housing carries an IP20 rating, indicating finger-safe access yet requiring placement in a protected electrical enclosure. A shared power supply concept lets several drives use one line module. No additional design features are specified. Firmware is ordered separately so the software release can be matched to the target machine.

Drive communication relies on the SERCOS III master with cross communication channel for deterministic cyclic data, while an auxiliary PROFIBUS port supports legacy PLC networks. Encoder feedback enters through the multiprotocol IndraDyn encoder interface for Hiperface and EnDat 2.1/2.2, enabling absolute position capture from Rexroth and third-party motors. Functional safety is built in through STO (Safe Torque Off) and SBC (Safe Brake Control), so axes can meet Category 3 and Performance Level d stop requirements without extra relays. Because the line series is HCS01, it integrates mechanically with narrow-width Rexroth power modules for decentralized machine layouts.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0003A02ACCECPBL4NNFW
  • HCS01 1E W0003 A 02 A CC EC PB L4 NN FW
  • hcs03.1e-w0150-a-05/s001
  • HCS1.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW:

Q: What communication protocol is supported by the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW controller?

A: This drive controller supports SERCOS III master (cross communication) for its primary communication interface.

Q: What mains voltage does the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW operate on?

A: The mains voltage required for this controller is 3-phase AC 110 to 230 V with a tolerance of plus or minus 10%.

Q: How is the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW cooled?

A: This model is cooled internally using an integrated blower for efficient thermal management.

Q: What safety features are included with the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW?

A: The device is equipped with STO (Safe Torque Off) and SBC (Safe Brake Control) as its safety interfaces.

Q: What is the peak current rating for the HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW drive controller?

A: The peak current capability of this controller is 3 A.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-A-CC-EC-PB-L4-NN-FW is an HCS drive controller with an ADVANCED control section. SERCOS III master cross communication and PROFIBUS support give the unit strong network flexibility for mixed automation architectures. IP20 protection and integrated STO/SBC safety functions make the controller a well-engineered choice for compact industrial drive systems.’’