HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW Bosch Rexroth Indramat
MPN: R911344556
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features SERCOS III communication, an ADVANCED control section, and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It provides a device peak current of 3 Amps, has an IP20 rating, and uses internal air cooling via an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat supplies the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW as an HCS drive controller for modular servo systems. The unit regulates compatible IndraDyn motors in automation racks and works with infeeding or fed power supply modules to manage closed-loop axis motion. Its control section is type A, and the design version is 1. This arrangement suits material handling, packaging, and general machine-tool applications where coordinated motion and compact cabinet layout are required. It is intended for cabinet-mounted installations where the drive and motor functions are distributed across coordinated system components.
The drive exchanges cyclic data over SERCOS III master (cross communication), which supports deterministic command transfer between linked axes. Heat is removed by air-through blower cooling, so airflow passes through the power section instead of relying on passive dissipation alone. The inverter can supply a device peak current of 3 A, allowing short load increases during acceleration and positioning. Position feedback on Interface 1 accepts IndraDyn Hiperface / EnDat 2.1 / 2.2 signals, and Interface 2 provides PROFIBUS for higher-level diagnostic exchange. The housing has an IP20 protection class that helps guard active parts against accidental contact inside an enclosure.
The paired ADVANCED control section adds faster processing and integrated safety functions for axis control. The mains input is rated for 3 × AC 110 to 230 V ±10 %, making the controller suitable for three-phase supply networks within that voltage range. When a fault condition is detected, the STO (Safe Torque Off) channel disables torque-producing output stages to support safe shutdown behavior. The unit fits IndraDrive layouts that use separate power modules and coordinated drives, and it supports applications that need compact installation, predictable response, and direct integration with compatible motor feedback systems.
Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW:
Q: Which communication interface is available on the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW controller?
A: The HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW supports a SERCOS III master interface for cross communication.
Q: What cooling method does the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW use?
A: This drive controller uses an internal air cooling method with an integrated blower for temperature management.
Q: What is the peak current capacity of the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW controller?
A: The peak current rating for this device is 3 amperes.
Q: What mains voltage does the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW require?
A: The controller operates with a main voltage range of 3 x AC 110 to 230 V plus or minus 10%.
Q: Which safety interface is included with the HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW drive controller?
A: The HCS01.1E-W0003-A-02-A-CC-EC-PB-L3-NN-FW features an STO, or Safe Torque Off, safety interface.