4.95 based on 202 reviews

🙶 Product was as advertised, got the machine back up and running at a fraction of OEM price. Delivered on ti... 🙷

HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911339700

No Tariffs On US Orders
  • Rated 4.4 (43 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW is an HCS IndraDrive Controller with an ADVANCED control section design. It features a SERCOS III master communication interface and air cooling through an integrated blower. The drive controller has a peak current of 3 Amps and operates with a mains voltage of 3 x AC 110 to 230 Volts with a ±10% tolerance.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW is a drive controller built by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. This compact unit supervises low-power servo axes by converting line supply energy into controlled three-phase output while exchanging status data with higher-level PLCs. Within an automation cell, it manages positioning, speed regulation, and drive diagnostics, serving as the electrical interface between motors and the control architecture. This makes the unit suitable for compact handling systems, indexing stations, and other machines that rely on coordinated servo motion.

The controller is delivered with an ADVANCED control section, so its internal signal processor and memory support multi-axis interpolation and diagnostic routines. Its mains input accepts 3 × AC 110–230 V ±10 %, which allows installation on utility networks common to light machinery. A device peak output of 3 A lets the unit accelerate and decelerate small servomotors without requiring an external braking resistor in many compact applications. Heat is removed by internal air cooling through an integrated blower, which eliminates the need for cabinet ducting. The enclosure has an IP20 rating, so the unit must be installed inside a protected electrical compartment while still providing fingertip protection against live parts.

For networked motion, the drive offers a SERCOS III master with cross communication port that synchronizes command cycles with neighboring drives. Motor feedback is read through IndraDyn Hiperface / EnDat 2.1 / 2.2 encoder support on Interface 1, while Interface 2 and the safety interface are not equipped. The internal DC link uses an infeeding and fed supply concept, allowing regenerated energy to be shared with other axes on the same link. The unit is built to Design Version 1 of the HCS01 line.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0003A02ACCECNNNNNNFW
  • HCS01 1E W0003 A 02 A CC EC NN NN NN FW
  • hcs03.1e-w0150-a-05-nnnv-aa
  • HCS1.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW:

Q: What is the maximum peak current provided by the HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW controller?

A: This controller supports a peak current of 3 A, accommodating standard servo drive demands in its category.

Q: How is the HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW features an integrated blower for internal air cooling.

Q: What communication interface is included with the HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW controller?

A: This model offers a SERCOS III master interface that allows for cross communication, enabling advanced networking with compatible devices.

Q: Which control section design type does the HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW utilize?

A: The control section is designed as the ADVANCED variant, providing expanded control capabilities over standard versions.

Q: What input mains voltage is required for the HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW?

A: The mains voltage range supported by this drive controller is 3 x AC 110 to 230 V with a 10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-A-CC-EC-NN-NN-NN-FW is an HCS drive controller that stands out with SERCOS III master cross communication and an ADVANCED control section. Internal air cooling through an integrated blower and IP20 protection support dependable cabinet integration, making the controller a strong choice for streamlined IndraDrive motion control.’’