HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW Bosch Rexroth Indramat
MPN: R911344537
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW is a HCS Drive Controller from the HCS IndraDrive Controllers series. It features an ADVANCED control section type, operates with a peak current of 3 Amps, and uses internal air cooling through an integrated blower. The drive supports SERCOS III cross communication, comes with MultiEthernet and encoder interfaces, and has an IP20 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW is a compact drive controller produced by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. It governs synchronous or induction axes when used with a matching power supply and motor feedback loop in an automation cell. The unit belongs to the HCS01 line and acts as the power section that carries out torque, speed, and position commands from the paired control section. Its compact format supports installation in control cabinets where coordinated axis control and dependable closed-loop response are required.
Incoming energy is accepted from a three-phase supply of 3 x AC 110 to 230 V ±10%, allowing the device to operate on low- to medium-voltage plant services. Peak output reaches 3 A, which is the maximum current available to the connected motor during dynamic transients. Heat generated by the IGBTs is removed by internal air cooling with an integrated blower, so no external ducting is required inside the panel. Protection against accidental contact follows the IP20 rating, which limits use to enclosed cabinets. Command data move across a deterministic SERCOS III master cross communication bus, enabling multi-axis synchronization over real-time Ethernet.
The controller is fitted with a MultiEthernet port for plant networks that rely on PROFINET, EtherNet/IP, or EtherCAT protocols, and it reads rotor position through IndraDyn Hiperface/EnDat 2.1/2.2 encoder feedback. Application parameters are handled by the ADVANCED control section, which plugs directly onto the power module and is identified as Design Version 1. The power unit supports infeeding and fed operation, so excess energy can return to a shared DC bus or be drawn from it during acceleration. This allows regenerated energy from one axis to be used elsewhere on the common bus instead of being wasted as heat.
Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW:
Q: What communication interface does the HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW support?
A: The HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW uses a SERCOS III master interface for cross communication.
Q: What is the peak current output capability of the HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW drive controller?
A: This model provides a device peak current rating of 3 A.
Q: How is the HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW cooled during operation?
A: Cooling is achieved by an internal integrated blower for air circulation within the unit.
Q: What is the second interface type provided on the HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW?
A: The HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW uses a MultiEthernet interface as its second interface type.
Q: What mains voltage does the HCS01.1E-W0003-A-02-A-CC-EC-ET-S4-NN-FW support?
A: This drive controller operates at a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.