4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW Bosch Rexroth Indramat

MPN: R911337831

No Tariffs On US Orders
  • Rated 4.7 (35 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features a peak device current of 3 Amps and a MultiEthernet interface. It has an IP20 rating and uses internal air cooling with an integrated blower.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat and supplied as part of the HCS IndraDrive Controllers series. It manages servo and spindle axes in factory automation. The unit combines motion control, power supply functions, and field communication in a compact housing intended for cabinet installation. This layout allows a single drive package to support controlled axis operation in packaging, handling, and other automated equipment.

The power electronics accept a three-phase mains input of 3 x AC 110 to 230 V ±10%, allowing the same hardware to operate from low or standard industrial line voltages. During acceleration, the inverter can supply up to 3 A of peak current to the connected motor, which suits low-power axes in compact machinery. Heat is removed by internal air cooling through an integrated blower, so no external fans or liquid circuits are required. The housing has an IP20 rating, which means live parts are protected against accidental contact but the unit must be installed inside a cabinet. An ADVANCED control section is fitted to the power unit, while a dedicated safety interface is not included. Because cooling air moves through the housing, cabinet placement should leave space for unobstructed airflow.

For axis communication, the drive provides a SERCOS III master with cross communication channel for real-time data exchange between neighboring drives. Feedback devices connect to an IndraDyn Hiperface or EnDat 2.1/2.2 encoder input, and higher-level network control can also use the built-in MultiEthernet interface for PROFINET, EtherNet/IP, or EtherCAT topologies. This combination supports local motion coordination while also linking the drive to common industrial Ethernet networks. Within the HCS01 line, this model is design version 1 and functions as an infeeding or feeder power supply.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0003A02ACCECETNNNNFW
  • HCS01 1E W0003 A 02 A CC EC ET NN NN FW
  • hcs03.1e-w0150-a-05-lnbv-aa
  • HCS1.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW drive controller?

A: The HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW features SERCOS III master for cross communication, enabling advanced automation bus integration.

Q: What is the peak current supported by the HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW controller?

A: This controller supports a device peak current of 3 A, suitable for low-to-moderate power applications.

Q: What is the cooling method used in the HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW?

A: Internal air cooling with an integrated blower is used in this model to maintain operating temperature.

Q: What design type is paired with the control section of the HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW?

A: The control section in this model uses the ADVANCED design type, providing enhanced configuration options.

Q: What mains voltage is required for the HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW drive controller?

A: The HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW is rated for 3-phase 110 to 230 V AC mains input, with a ±10% tolerance.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-A-CC-EC-ET-NN-NN-FW is an HCS drive controller with an ADVANCED control section and IP20 protection. SERCOS III master cross communication and MultiEthernet support give the unit strong integration flexibility for modern motion systems. Internal air cooling through an integrated blower supports stable thermal performance, making the controller a very capable choice for compact industrial drive applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo