HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW Bosch Rexroth Indramat
MPN: R911339699
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a SERCOS III master communication interface with cross communication and supports MultiEthernet connectivity. It has an internal air cooling method with an integrated blower, a device peak current of 3 Amps, and includes STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW is a modular drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. As an axis inverter, it links servo motors to higher-level motion platforms and supplies regulated power, feedback handling, and safety functions for industrial automation lines, pick-and-place gantries, and packaging machinery. Its compact HCS01 format supports installation in control cabinets where depth is limited, and the design is suited to machine sections that need responsive axis control without a large drive footprint. This makes it appropriate for smaller servo axes that still require coordinated communication and integrated control features.
This controller operates from a three-phase supply of 3 x AC 110...230 V ±10%, allowing direct connection to low-voltage factory mains. Internally, it can deliver up to 3 A of peak output current, which suits low-power IndraDyn synchronous motors used on auxiliary axes and similar motion tasks. Thermal management uses internal air cooling through an integrated blower, so cabinet air is circulated across the heat sink without external ducting or separate cooling hardware. Motion commands are exchanged through a SERCOS III master with cross communication channel, which supports real-time data exchange between drives for synchronized operation. All axis functions run on an ADVANCED control section that provides expanded processing for interpolation, diagnostics, and embedded safety tasks.
Position and velocity feedback enter through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while higher-level PLCs can also reach the unit through MultiEthernet, which supports PROFINET, EtherNet/IP, and EtherCAT networks. Housing protection is rated IP20, so the controller is finger-safe when installed inside a suitable enclosure. Emergency stop circuits can remove torque through STO (Safe Torque Off), which is integrated into the base hardware. The unit is version 1 and is supplied with an infeeding power module. The controller is intended for cabinet installation, and its integrated interfaces allow motion control, network communication, and safety shutdown functions to be handled within the same platform.
Frequently Asked Questions about HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW:
Q: What cooling method is implemented in the HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW drive controller?
A: The HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW uses air cooling with an internal integrated blower for temperature management.
Q: What is the peak current rating of the HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW?
A: This controller supports a maximum peak device current of 3 A during operation.
Q: What level of protection does the IP20 rating offer for the HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW?
A: The IP20 rating of this model specifies it is protected against solid objects larger than 12.5 mm and does not provide water protection.
Q: Which communication interface does the HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW utilize?
A: The controller features SERCOS III cross communication as its main communication interface.
Q: What mains voltage does the HCS01.1E-W0003-A-02-A-CC-EC-ET-L3-NN-FW support?
A: The mains voltage for this IndraDrive Controller ranges from 3 x AC 110 to 230 V with a tolerance of ±10%.