HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat
MPN: R911325247
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and an IP20 protection rating. It has a peak device current of 18 Amps and supports air cooling through an integrated blower.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. As a cabinet-mounted unit, it conditions three-phase power, regulates motor current, and exchanges status data with plant PLCs so automated packaging lines, pick-and-place stations, and material-handling axes can run with coordinated speed, torque, and position profiles. Its cabinet installation keeps the electronics protected inside a larger enclosure while allowing the controller to serve as the central power stage for a single axis or a compact machine section.
On the network side, it supports MultiEthernet, enabling direct integration with EtherNet/IP, PROFINET, or EtherCAT without external converters. The power stage accepts 3 x AC 200...500 V ±10%, allowing operation in facilities that use either 230 V or 480 V mains. During dynamic events, the inverter delivers up to 18 A of peak current, while internal air cooling through an integrated blower removes switching losses without additional ductwork. The housing is rated IP20, which helps prevent accidental contact and is intended for installation inside an electrical enclosure. Interface 2 and the safety interface are not equipped, so stop and emergency-stop functions must be provided by external hardware.
The control section is classified as BASIC and is intended for standard motion tasks. Feedback is handled through an IndraDyn encoder with Hiperface or EnDat 2.1/2.2, allowing the drive to read position data at power-up. The unit is design version 1. The power module supports infeeding and fed operation, so it can supply regenerative energy to a shared DC bus or receive energy from an upstream rectifier. This arrangement suits multi-axis installations that use a shared DC-bus structure across several drives.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW:
Q: What type of communication interface is included on the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW features a MultiEthernet communication interface for flexible network integration.
Q: What is the device peak current capability of the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW?
A: This drive controller supports a device peak current of 18 A during operation.
Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW drive controller cooled?
A: The cooling for this model is provided by an internal integrated blower using air circulation.
Q: What is the mains voltage requirement for the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW operates with a mains voltage of three-phase AC 200 to 500 V ±10%.
Q: What control section design type is used in the HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW?
A: This controller is paired with a BASIC control section design, as indicated by its configuration.