HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW Bosch Rexroth Indramat
MPN: R911396314
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, device peak current of 18 Amps, and operates with a mains voltage of 3 x AC 200 to 500 Volts. The unit uses internal air cooling through an integrated blower and supports encoder interfaces like IndraDyn Hiperface and EnDat 2.1/2.2, with IP20 protection and STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It interfaces between a three-phase mains supply and servo or induction motors, executing velocity, position, and torque commands issued by a plant PLC. By combining an inverter stage, encoder evaluation, and fieldbus connectivity in one housing, it helps simplify cabinet layouts for packaging lines, handling stations, and general motion axes. This arrangement lets one unit manage motor power conversion and motion feedback without requiring separate control hardware for routine axis tasks.
It supports a supply of 3 x AC 200–500 V (±10%), so the same hardware can operate across a wide range of industrial mains systems. During acceleration, the power stage can source up to 18 A peak, which is the maximum short-term motor current available during brief demand changes. Functional safety is provided by the STO input, which disables gate signals and prevents unintended torque. With an IP20 enclosure, the device is suited for protected electrical cabinets where only solid-object ingress must be blocked. System buses connect through MultiEthernet, allowing one interface port to run EtherNet/IP, PROFINET, or EtherCAT for cyclic data exchange and diagnostics without extra option modules.
The controller is fitted with a BASIC control section that supplies standard drive functions such as speed control, homing, and simple positioning. Cooling air moves through an internal blower, so external ducting is unnecessary. Motor feedback is accepted over the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling single-cable technology with compatible motors. The unit is Design Version 1, and the integrated DC link can work in infeeding or regenerative mode, sending excess energy back to the bus during braking events.
Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW:
Q: What type of communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW controller?
A: The HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW utilizes a MultiEthernet communication interface for flexible and modern networking.
Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW drive controller cooled?
A: This model is cooled internally through an integrated blower, ensuring effective temperature management.
Q: What is the peak current capability of the HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW controller?
A: The device supports a peak current of 18 A for dynamic performance in demanding applications.
Q: What mains voltage does the HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW support?
A: The mains voltage range for this controller is 3 x AC 200 to 500 V with a tolerance of ±10%.
Q: What type of safety interface is integrated in the HCS01.1E-W0018-A-03-B-ET-EC-DA-L3-NN-FW drive controller?
A: The safety interface on this controller provides STO (Safe Torque Off) functionality.