4.95 based on 202 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911377265

No Tariffs On US Orders
  • Rated 4.5 (65 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface, supports IP20 protection, and has a peak current of 18 Amps. The controller uses an internal air cooling method through an integrated blower and operates with a mains voltage of 3 x AC 200 to 500 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW is a single-axis drive controller in the HCS IndraDrive Controllers series from Bosch Rexroth Indramat. It combines power conversion, motion control, and communication in one housing to operate servo or asynchronous motors in conveyors, pick-and-place systems, and similar automated equipment. By converting incoming three-phase power into controlled motor output, the unit supports accurate current and voltage regulation during positioning and speed-control tasks. Its integrated design helps reduce the number of separate modules needed for a compact machine axis and keeps power, feedback, and network functions in one device.

The controller accepts a mains supply of 3 x AC 200…500 V ±10%, allowing use across a broad industrial voltage range. During short acceleration peaks, the inverter can deliver up to 18 A of peak current to support temporary overload demand. The enclosure has an IP20 rating, so the unit is intended for installation inside a control cabinet. Network communication is handled through the MultiEthernet interface, and motor feedback is connected through an Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port for compatible encoder systems. This combination allows the drive to exchange command data with the control system while also receiving rotor position signals needed for closed-loop operation.

A separate motion bus uses CANopen for real-time coordination with other machine components. The installed control section is the BASIC variant, which provides the core control functions for standard axis applications. Thermal management uses internal air cooling through an integrated blower, which removes heat without external ducting. The power stage supports an infeeding and feeding DC-link concept, allowing regenerated energy to be shared with other connected axes. This arrangement is useful in multi-axis systems where one axis can absorb energy returned by another during braking.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
CANopen
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A03BETECCNS4NNFW
  • HCS01 1E W0018 A 03 B ET EC CN S4 NN FW
  • #REF!
  • hcs01.1e-w0018-a-02-b-et-ec-ep-nn-nn-fw
  • HCS1.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW
  • hcs01.1e-w0018-a-03-b-et-ec-cn-s4-nn-fw
  • HCS1.1E-W18-A-3-B-ET-EC-CN-S4-NN-FW
  • hcs011ew0018a03beteccns4nnfw
  • HC501.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCSO1.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS0I.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.IE-W0018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-WO018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W0O18-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W00I8-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W001B-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W0018-A-O3-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W0018-A-03-8-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W0018-A-03-B-ET-EC-CN-54-NN-FW
  • HC5OI.IE-WOOIB-A-O3-8-ET-EC-CN-54-NN-FW
  • HCS01.1E-W018-A-03-B-ET-EC-CN-S4-NN-FW
  • HCS01.1E-W0018-A-3-B-ET-EC-CN-S4-NN-FW
  • HCS01.1EW0018-A-03-B-ET-EC-CN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW drive controller?

A: This model features a MultiEthernet communication interface, enabling versatile network connectivity.

Q: What is the device peak current for this HCS IndraDrive Controller model?

A: The HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW provides a peak current of 18 A, supporting high-demand applications.

Q: How is the HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW cooled?

A: Cooling is achieved through internal air circulation using an integrated blower in this controller.

Q: What mains voltage range does the HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW support?

A: This controller operates with a 3-phase AC voltage range of 200 to 500 V with ±10% tolerance.

Q: What is the IP rating of the HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW?

A: The protection level for this drive controller is IP20, providing basic protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-03-B-ET-EC-CN-S4-NN-FW is a HCS IndraDrive Controller from Bosch Rexroth Indramat, designed with a MultiEthernet communication interface and a BASIC control section. It features an internal air cooling method utilizing an integrated blower and delivers a peak device current of 18 A. This controller stands out for its versatility and reliable performance in demanding automation environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo