HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW Bosch Rexroth Indramat
MPN: R911341860
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a MultiEthernet communication interface and operates with a device peak current of 18 Amps. The unit uses internal air cooling through an integrated blower and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat and assigned to the HCS IndraDrive Controllers series. Inside an HCS01 power section, it delivers regulated DC link energy to connected motors while the paired BASIC control section executes motion commands and diagnostics. Used in industrial automation cells, this unit supplies the torque and speed regulation demanded by conveyors, pick-and-place axes, and forming machines while remaining compact for panel installation.
The drive accepts a three-phase supply of 3 × AC 110…230 V ±10%, allowing low-voltage plants to share a common bus without additional transformers. From that input, it can deliver up to 18 A of peak output current, giving short-term headroom for acceleration or load shocks. Its internal bus arrangement supports infeeding and fed operation, so the device can either receive DC energy from an upstream rectifier or act as the rectifier for a small group of drives. Protection is based on an IP20 housing, which keeps fingers and tools away from live parts but requires installation in a closed cabinet. Thermal management relies on internal air cooling through an integrated blower, and the built-in fan moves enclosure air over the heat sink without external ducting.
For higher-level coordination, the controller offers MultiEthernet connectivity, enabling real-time exchange over EtherNet/IP, PROFINET, or EtherCAT without additional option cards. Motor feedback is processed through the single-cable IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while the second feedback port is left vacant for applications that do not require dual-loop sensing. The control electronics follow the BASIC design classification, which suits machines that need standard positioning functions rather than advanced safety or PLC features. The unit is Design Version 1.
Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW:
Q: What communication interface is available on the HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW drive controller?
A: The HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW supports MultiEthernet communication for flexible network integration.
Q: What is the device peak current for the HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW?
A: This controller has a device peak current rating of 18 A, allowing for short bursts of high current during operation.
Q: What cooling method is employed by the HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW controller?
A: The HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW uses internal air cooling through an integrated blower to maintain optimal temperature.
Q: What IP rating does the HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW drive controller have?
A: This model offers an IP20 rating, which provides basic protection against solid objects but no protection against water.
Q: What mains voltage range is supported by the HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW controller?
A: The HCS01.1E-W0018-A-02-B-ET-EC-NN-S4-NN-FW operates on a mains voltage of 3 x AC 110 to 230 V with ±10% tolerance.