4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW Bosch Rexroth Indramat

MPN: R911378684

No Tariffs On US Orders
  • Rated 4.5 (63 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW belongs to the HCS IndraDrive Controllers series and is a drive controller with a peak current of 18 Amps. It features MultiEthernet communication, supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2, and uses internal air cooling with an integrated blower. The controller has an IP20 rating and operates at a mains voltage of 3 x AC 110 to 230 Volts.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW belongs to the HCS IndraDrive Controllers series, a line of modular inverters used for single-axis motion tasks in industrial automation. The controller serves as the power and communication link between a PLC and a connected motor, regulating current, speed, and position while monitoring load and temperature conditions. By combining power electronics and fieldbus connectivity in a compact housing, it helps simplify cabinet layout for packaging units, small conveyors, and assembly stations that require precise drive control.

The unit communicates with supervisory systems through MultiEthernet, allowing selection of PROFINET, EtherNet/IP, or EtherCAT without hardware changes. Its input stage accepts 3 × AC 110…230 V ±10%, which supports operation in facilities that use either 120 V or 208 V distribution. A current stage rated for 18 A peak supports the short acceleration bursts required by indexing axes. Rotor feedback is received through an Encoder IndraDyn Hiperface / EnDat 2.1 / 2.2 interface, so high-resolution position data reaches the servo loop without external converters. The IP20 housing limits access to energized parts and is intended for installation inside a switchgear enclosure that manages environmental exposure and EMC shielding.

The drive uses a BASIC control section that provides standard PLCI, safety, and parameter memory functions for general-purpose machinery. Internal circuitry is cooled by internal blower cooling, so normal cabinet airflow is sufficient without added ventilation ducts. The power module uses an infeeding and fed topology, which allows shared DC bus energy exchange when multiple axes brake or accelerate at the same time. The unit is design version 1, indicating the first design revision of this configuration.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
18 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0018A02BETECEPS4NNFW
  • HCS01 1E W0018 A 02 B ET EC EP S4 NN FW
  • #REF!
  • hcs01.1e-w0013-a-02-b-et-ec-nn-l4-nn-aw
  • HCS1.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW
  • hcs01.1e-w0018-a-02-b-et-ec-ep-s4-nn-fw
  • HCS1.1E-W18-A-2-B-ET-EC-EP-S4-NN-FW
  • hcs011ew0018a02beteceps4nnfw
  • HC501.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCSO1.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS0I.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.IE-W0018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-WO018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0O18-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W00I8-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W001B-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0018-A-O2-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0018-A-0Z-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0018-A-02-8-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0018-A-02-B-ET-EC-EP-54-NN-FW
  • HC5OI.IE-WOOIB-A-OZ-8-ET-EC-EP-54-NN-FW
  • HCS01.1E-W018-A-02-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0018-A-2-B-ET-EC-EP-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW:

Q: What communication interface does the HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW support?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW offers MultiEthernet communication interface for flexible network connectivity.

Q: What is the peak current supported by the HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW?

A: This drive controller is capable of handling a device peak current of 18 A during operation.

Q: How does the HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW controller stay cool during use?

A: Cooling is achieved internally with an integrated blower using air circulation within the device.

Q: What mains voltage range is required for the HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW?

A: The HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW operates at a mains voltage of 3 x AC 110 to 230 V ±10%.

Q: What is the IP rating of the HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW drive controller?

A: This unit is equipped with an IP20 protection rating, indicating limited protection against dust and no protection against liquids.


Internal Product Review

  • ‘‘The HCS01.1E-W0018-A-02-B-ET-EC-EP-S4-NN-FW is a versatile drive controller from the HCS IndraDrive series, offering MultiEthernet communication and a peak current of 18 A. Its integrated internal air blower provides effective cooling, while IP20 protection ensures reliable operation in industrial settings. This model is a solid choice for efficient drive control where flexible communication and dependable thermal management are required.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo