4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat

In-Stock, Ships 1-2 Days

Current response time:
5 Minutes 40 Seconds

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series and features a peak device current of 13 Amps. Equipped with a MultiEthernet communication interface, it uses internal air cooling through a built-in blower and provides IP20 protection. This drive controller supports mains voltage from 110 to 230 Volts AC and has an encoder interface compatible with IndraDyn Hiperface and EnDat protocols.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. Designed as an axis inverter for low-power stages, the unit converts the incoming three-phase supply, regulates motor current, and exchanges status data with higher-level PLCs during operation. Within an automated line, it provides closed-loop speed, torque, and position control for compact handling modules, indexers, and auxiliary process drives. It belongs to the HCS01 line and supports modular control sections and power supplies matched to individual machine layouts.

Electrical input is a balanced three-phase supply of 3 x AC 110–230 V ±10%, allowing the controller to be mounted on systems fed by standard low-voltage distribution networks. During dynamic acceleration, it can source up to 13 A of peak output current to the connected motor phases. Heat generated by switching transistors is removed by internal air cooling through an integrated blower, so no external ducting is necessary inside the cabinet. The housing carries an IP20 rating, which provides finger-safe protection but requires installation in an enclosure. For communication, a MultiEthernet port supports PROFINET, EtherNet/IP, and EtherCAT without additional option cards, allowing flexible network integration.

The power section is paired with a BASIC control board in version 1, which executes motion profiles and manages parameters. Feedback from synchronous or asynchronous motors is accepted through the IndraDyn, Hiperface, and EnDat 2.1/2.2 encoder interface, while the second encoder slot is left empty, which keeps the configuration focused on a single feedback channel. DC link energy is supplied by an infeeding power module, so the device can share regenerated power with adjacent axes. Safety and additional fieldbus interfaces are not fitted, so the controller remains focused on its basic motion and network functions.

Communication Interface
MultiEthernet
Connection Voltage
110?230V
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Cooling Mode
Internal Air
Design Version
1
Device Peak Current
13 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Maximum Current
13 A
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS01.1EW0013A02BETECNNNNNNFW
  • HCS011E-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS011EW0013A02BETECNNNNNNFW
  • HCSO1.1E-WOO13-A-O2-B-ET-EC-NN-NN-NN-FW
  • HCS01 1E W0013 A 02 B ET EC NN NN NN FW
  • #REF!
  • hcs01.1e-w0013-a-02-a-cc-ec-ec-l3-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • hcs01.1e-w0013-a-02-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W13-A-2-B-ET-EC-NN-NN-NN-FW
  • hcs011ew0013a02betecnnnnnnfw
  • HC501.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCSO1.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS0I.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.IE-W0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-WO013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0O13-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W00I3-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0013-A-O2-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0013-A-0Z-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0013-A-02-8-ET-EC-NN-NN-NN-FW
  • HC5OI.IE-WOOI3-A-OZ-8-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0013-A-2-B-ET-EC-NN-NN-NN-FW
  • HCS01.1EW0013-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0013A-02-B-ET-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW drive controller?

A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW controller supports MultiEthernet communication interface for flexible connectivity.

Q: What is the device peak current of the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW controller?

A: This drive controller has a peak current rating of 13 A, allowing it to handle applications with moderate power requirements.

Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW drive controller cooled?

A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW features air cooling via an integrated internal blower for efficient temperature management.

Q: What is the mains voltage specification for the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW controller?

A: This controller supports a mains voltage input of 3 x AC 110 to 230 V with a tolerance of ±10%.

Q: What is the IP rating of the HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW controller?

A: The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW comes with IP20 protection, offering limited ingress protection against solid objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0013-A-02-B-ET-EC-NN-NN-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and IP20 protection support stable cabinet operation in standard industrial installations. A 13 A peak current rating with 3 x AC 110 to 230 V mains input makes this unit a strong fit for compact IndraDrive motion systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo