4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345318

Ask for Availability
Current Response Time 6 min 45 sec

The Bosch Rexroth Indramat HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a peak current of 13 Amps and supports MultiEthernet communication. This device uses air cooling through an integrated blower and operates with an IP20 protection rating at a mains voltage of 3 x AC 110 to 230 Volts.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW is a drive controller from the Bosch Rexroth IndraDrive series, equipped with MultiEthernet communication and BASIC control section design. Internal air cooling via an integrated blower ensures thermal efficiency, and the device delivers a peak current of 13 A. With IP20 protection and support for IndraDyn Hiperface/EnDat encoder interfaces, this controller is a dependable choice for modern automation systems.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW is a compact drive controller released by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Intended for low- to medium-power servo axes, the unit supplies closed-loop motor regulation, diagnostics, and fieldbus connectivity in distributed automation cells. By combining power electronics and motion logic in one housing, it links the machine PLC to synchronous or asynchronous motors and supports speed, torque, and position control without separate amplifier modules. This arrangement helps keep panel layouts compact while centralizing axis regulation in a single controller.

Its input section tolerates a three-phase supply of 3 × AC 110…230 V ±10 %, allowing deployment on worldwide utility grids without a step-down transformer. Protection against direct finger contact is provided by the IP20 enclosure class, so the unit must be installed inside a cabinet. Thermal management relies on internal air cooling through an integrated blower, and the fan moves air across the heat sink without external ducting. At acceleration or braking peaks, the inverter can deliver up to 13 A of device current, which sets the maximum motor size that can be paired with this controller frame. Network traffic is routed through a MultiEthernet port, giving simultaneous support for PROFINET, EtherNet/IP, and EtherCAT topologies so the same controller can fit different plant standards.

The power stage is paired with the BASIC control section, which provides motion functions and parameter memory in a pluggable format. Both feedback sockets accept Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals, enabling high-resolution position data from compatible Rexroth and third-party motors. The unit is Design Version 1, which identifies the initial release layout for this model. Energy can be returned or drawn through the infeed/feed power supply concept, allowing common DC bus operation in multi-axis arrangements. This setup supports coordinated drive operation where multiple axes share power and feedback resources within the same system.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
13 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller

Frequently Asked Questions about HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW:

Q: What type of communication interface does the HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW controller use?

A: This unit utilizes MultiEthernet as its communication interface for connectivity.

Q: What is the peak current supported by the HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW drive controller?

A: It supports a device peak current of 13 A.

Q: How is the HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW controller cooled?

A: Cooling is achieved internally through an integrated blower with air circulation.

Q: What encoder interface types are available on the HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW?

A: This controller features two encoder interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.

Q: What is the IP rating of the HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW?

A: The HCS01.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW is designed with an IP20 protection rating.

  • HCS011EW0013A02BETECECS4NNFW
  • HCS01 1E W0013 A 02 B ET EC EC S4 NN FW
  • #REF!
  • hcs01.1e-w0009-a-02-b-et-ec-nn-l3-nn-fw
  • HCS1.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW
  • hcs01.1e-w0013-a-02-b-et-ec-ec-s4-nn-fw
  • HCS1.1E-W13-A-2-B-ET-EC-EC-S4-NN-FW
  • hcs011ew0013a02betececs4nnfw
  • HC501.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCSO1.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS0I.1E-W0013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.IE-W0013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-WO013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0O13-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W00I3-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0013-A-O2-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0013-A-0Z-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0013-A-02-8-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0013-A-02-B-ET-EC-EC-54-NN-FW
  • HC5OI.IE-WOOI3-A-OZ-8-ET-EC-EC-54-NN-FW
  • HCS01.1E-W013-A-02-B-ET-EC-EC-S4-NN-FW
  • HCS01.1E-W0013-A-2-B-ET-EC-EC-S4-NN-FW
  • HCS01.1EW0013-A-02-B-ET-EC-EC-S4-NN-FW
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo