4.95 based on 202 reviews

🙶 Easy to navigate website and quick responses from support. Additionally, pretty fast shipping. Our mainte... 🙷

HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and supports mains voltages of 3 x AC 110 to 230 volts. It has a peak current of 9 Amps, includes an internal air cooling system with an integrated blower, and has an IP20 rating.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Designed for panel installation, the unit connects a three-phase utility supply to a single-axis servo or induction motor and generates regulated output current that follows motion commands from a PLC or CNC. In automated equipment, it carries out velocity, torque, and position functions while returning operating data to the higher-level control system for closed-loop machine operation.

It accepts a mains input of 3 x AC 110…230 V ±10%, allowing one cabinet design to serve both North American and international low-voltage installations. The power stage can deliver a peak current of 9 A, which supports short bursts of torque during acceleration or rapid indexing. Heat generated by the switching devices is removed through internal blower cooling, so no external ducting is required. Cabinet protection is limited to IP20, which means the surrounding enclosure must prevent contact with live parts. Communication is handled through a MultiEthernet port that supports common industrial Ethernet protocols, allowing the controller to connect to mixed network environments without extra gateways.

The power section is paired with a BASIC control section, providing standard axis functions without integrated safety extensions. The unit is Version 1. For motor feedback, Interface 1 accepts an IndraDyn Hiperface/EnDat 2.1/2.2 encoder signal for high-resolution position control. The second feedback interface is not equipped, which helps conserve space in the housing. Energy is managed through an infeeding and fed supply concept that allows multiple drives to share a common DC bus. Because the safety interface is omitted, external devices must handle machine guarding.

Communication Interface
MultiEthernet
Connection Voltage
110?230V
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Cooling Mode
Internal Air
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Maximum Current
9 A
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02BETECNNNNNNFW
  • HCS01 1E W0009 A 02 B ET EC NN NN NN FW
  • #REF!
  • hcs01.1e-w0008-a-03-b-et-ec-pb-nn-nn-fw
  • HCS1.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW
  • hcs01.1e-w0009-a-02-b-et-ec-nn-nn-nn-fw
  • HCS1.1E-W9-A-2-B-ET-EC-NN-NN-NN-FW
  • hcs011ew0009a02betecnnnnnnfw
  • HC501.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCSO1.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS0I.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.IE-W0009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-WO009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0O09-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W00O9-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0009-A-O2-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0009-A-0Z-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0009-A-02-8-ET-EC-NN-NN-NN-FW
  • HC5OI.IE-WOOO9-A-OZ-8-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0009-A-2-B-ET-EC-NN-NN-NN-FW
  • HCS01.1EW0009-A-02-B-ET-EC-NN-NN-NN-FW
  • HCS01.1E-W0009A-02-B-ET-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW:

Q: What communication interface is provided on the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW drive controller?

A: This controller supports MultiEthernet as its primary communication interface for flexible network integration.

Q: What is the maximum peak current supported by the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW?

A: The controller has a peak current capability of 9 A, suitable for moderate power applications.

Q: What mains voltage range does the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW support?

A: The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW operates with a 3-phase AC supply voltage ranging from 110 to 230 V ±10%.

Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW cooled during operation?

A: Integrated internal air cooling is used in this model, achieved through a built-in blower system.

Q: Which encoder interfaces are available on the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW drive controller?

A: This controller's encoder interface is compatible with IndraDyn, Hiperface, and EnDat 2.1/2.2 feedback devices.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is an HCS drive controller with MultiEthernet communication and a BASIC control section. Internal blower cooling and IP20 protection make the controller a strong choice for enclosed automation systems.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo