HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911326040
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is part of the HCS IndraDrive Controllers series. This drive controller features a MultiEthernet communication interface and supports mains voltages of 3 x AC 110 to 230 volts. It has a peak current of 9 Amps, includes an internal air cooling system with an integrated blower, and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Designed for panel installation, the unit connects a three-phase utility supply to a single-axis servo or induction motor and generates regulated output current that follows motion commands from a PLC or CNC. In automated equipment, it carries out velocity, torque, and position functions while returning operating data to the higher-level control system for closed-loop machine operation.
It accepts a mains input of 3 x AC 110…230 V ±10%, allowing one cabinet design to serve both North American and international low-voltage installations. The power stage can deliver a peak current of 9 A, which supports short bursts of torque during acceleration or rapid indexing. Heat generated by the switching devices is removed through internal blower cooling, so no external ducting is required. Cabinet protection is limited to IP20, which means the surrounding enclosure must prevent contact with live parts. Communication is handled through a MultiEthernet port that supports common industrial Ethernet protocols, allowing the controller to connect to mixed network environments without extra gateways.
The power section is paired with a BASIC control section, providing standard axis functions without integrated safety extensions. The unit is Version 1. For motor feedback, Interface 1 accepts an IndraDyn Hiperface/EnDat 2.1/2.2 encoder signal for high-resolution position control. The second feedback interface is not equipped, which helps conserve space in the housing. Energy is managed through an infeeding and fed supply concept that allows multiple drives to share a common DC bus. Because the safety interface is omitted, external devices must handle machine guarding.
Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW:
Q: What communication interface is provided on the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW drive controller?
A: This controller supports MultiEthernet as its primary communication interface for flexible network integration.
Q: What is the maximum peak current supported by the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW?
A: The controller has a peak current capability of 9 A, suitable for moderate power applications.
Q: What mains voltage range does the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW support?
A: The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW operates with a 3-phase AC supply voltage ranging from 110 to 230 V ±10%.
Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW cooled during operation?
A: Integrated internal air cooling is used in this model, achieved through a built-in blower system.
Q: Which encoder interfaces are available on the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW drive controller?
A: This controller's encoder interface is compatible with IndraDyn, Hiperface, and EnDat 2.1/2.2 feedback devices.