The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW is part of the HCS IndraDrive Controllers series. This HCS drive controller features a MultiEthernet communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. It uses internal air cooling with an integrated blower and is designed with IP20 protection while operating with a peak current of 9 Amps.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW is a drive controller manufactured by Bosch Rexroth Indramat and supplied within the HCS IndraDrive Controllers series. As an axis inverter, it couples directly to plant mains and delivers regulated three-phase output for servo and asynchronous motors used in material-handling cells, packaging machinery, and pick-and-place stations. It regulates motor voltage and current so commanded speed and torque can be maintained during cycle changes and load variations. Integrating motion functions into the drive helps reduce cabinet space and keeps power and control hardware concentrated in one enclosure. This layout supports compact machine panels where several automation modules must be installed side by side.
The power section accepts 3 × AC 110…230 V ±10%, so the same unit can operate from single-phase or low-voltage three-phase supplies. Internally it can provide up to 9 A of peak current during short acceleration periods. Thermal limits are managed by internal air cooling through an integrated blower, which moves cabinet air across the heat sink. Because the cooling method uses enclosure air, the panel must provide a clear airflow path around the drive. A Multi-Ethernet port supports EtherNet/IP, PROFINET, and EtherCAT from one connector, and the housing has an IP20 rating for finger-safe installation inside an electrical enclosure.
The controller is supplied with the BASIC control section in design version 1, which suits standard single-axis applications. Feedback is handled through the integrated IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, while the secondary encoder slot and safety interface are not equipped. Without those additional interfaces, the hardware is arranged for one primary motor feedback channel rather than expanded feedback or safety functions. The power module supports infeeding or fed operation, so it can draw DC-bus energy from an external supply or provide it to additional axes. Within the HCS01 line, this power section is paired with BASIC control sections only.
Frequently Asked Questions about HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW:
Q: What type of communication interface does the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW controller use?
A: The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW features a MultiEthernet communication interface for versatile network connectivity.
Q: What is the maximum peak current supported by the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW drive controller?
A: This model supports a peak device current of 9 A, enabling it to handle significant load requirements.
Q: How is the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW cooled during operation?
A: The controller utilizes an air cooling system with an integrated blower for internal thermal management.
Q: What mains voltage range does the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW support?
A: It operates on a mains voltage of 3 x AC 110 to 230 V with a tolerance of plus or minus 10%.
Q: What level of protection does the IP20 rating provide for the HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-AA-FW?
A: The device is rated with an IP20 enclosure, meaning it is protected against solid objects over 12 mm but is not water-resistant.