The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW is part of the HCS IndraDrive Controllers series and features a SERCOS III master communication interface. This drive controller uses internal air cooling with an integrated blower, has a peak current of 9 Amps, and operates at 3 x AC 110 to 230 Volts with ±10% tolerance. It provides STO Safe Torque Off and SBC Safe Brake Control safety interfaces, and has an IP20 protection rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. Supplied as design version 1, this unit serves as a compact power and regulation stage for servo axes in packaging, printing, and general automation lines. As an HCS drive controller, it conditions incoming three-phase mains power, performs closed-loop current control, and communicates status data to a plant-level PLC so that motion sequences remain synchronized. Its compact format makes it suitable for cabinet installations where coordinated axis control is required without the larger footprint of higher-power drive classes.

For deterministic multi-axis coordination, the controller includes a SERCOS III master (cross communication) port. Its control section uses the ADVANCED design, and thermal management is handled by internal air cooling through an integrated blower rather than external ducting. Peak output capability reaches 9 A, allowing the drive to operate small to mid-frame IndraDyn motors during acceleration and regulated motion. The input range of 3 x AC 110 to 230 V ±10% supports use with different plant supply systems, and the unit is not equipped with a second encoder interface.

The enclosure has a protection rating of IP20, so it is intended for installation inside a closed control cabinet. Motor feedback is connected through a single interface that accepts Encoder IndraDyn Hiperface/EnDat 2.1/2.2 signals for position capture and drive control. Integrated safety includes STO (Safe Torque Off) and SBC (Safe Brake Control), allowing the drive to remove motor torque and manage the brake control path through built-in safety functions. The power section is intended for infeeding and fed operation, so it can receive DC bus energy from an upstream supply and exchange regenerated energy with neighboring drives on the same system.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
  • HCS011EW0009A02ACCECNNL4NNFW
  • HCS01 1E W0009 A 02 A CC EC NN L4 NN FW
  • #REF!
  • hcs01.1e-w0008-a-03-b-et-ec-ec-s5-nn-fw
  • HCS1.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW
  • hcs01.1e-w0009-a-02-a-cc-ec-nn-l4-nn-fw
  • HCS1.1E-W9-A-2-A-CC-EC-NN-L4-NN-FW
  • hcs011ew0009a02accecnnl4nnfw
  • HC501.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCSO1.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS0I.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.IE-W0009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-WO009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W0O09-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W00O9-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W0009-A-O2-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W0009-A-0Z-A-CC-EC-NN-L4-NN-FW
  • HC5OI.IE-WOOO9-A-OZ-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W0009-A-2-A-CC-EC-NN-L4-NN-FW
  • HCS01.1EW0009-A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1E-W0009A-02-A-CC-EC-NN-L4-NN-FW
  • HCS01.1EW0009A-02-A-CC-EC-NN-L4-NN-FW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW:

Q: What communication interface is available on the HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW controller?

A: The HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW supports SERCOS III master for cross communication.

Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW cooled?

A: This drive controller uses internal air cooling through an integrated blower for temperature management.

Q: What is the peak current supported by the HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW?

A: The device can handle a peak current of 9 A during operation.

Q: What is the allowed mains voltage range for the HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW?

A: This model has a mains voltage range of 3 x AC 110...230 V with a tolerance of ±10%.

Q: What safety interfaces are provided on the HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW drive controller?

A: The controller features STO (Safe Torque Off) and SBC (Safe Brake Control) as its safety interface options.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-CC-EC-NN-L4-NN-FW is an advanced HCS IndraDrive Controller from Bosch Rexroth Indramat, featuring a SERCOS III master communication interface and an integrated encoder interface supporting IndraDyn Hiperface/EnDat 2.1/2.2. Internal air cooling with a built-in blower provides efficient thermal management, while IP20 protection and a peak device current of 9 A ensure reliable operation in standard automation environments. The inclusion of STO (Safe Torque Off) and SBC (Safe Brake Control) highlights the controller's emphasis on safety.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo