The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW is a drive controller from the HCS IndraDrive Controllers series. This controller uses a SERCOS III master communication interface and supports a MultiEthernet interface. It features an internal air cooling blower and can deliver a peak current of 9 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW is a drive controller from the HCS IndraDrive Controllers series manufactured by Bosch Rexroth Indramat. It occupies the control layer of an automation cell and converts command data into regulated drive current for connected IndraDyn motors. Within a machine line, the unit coordinates speed, torque, and position loops so that actuators follow motion profiles sent by the higher-level PLC.

A cross-communication channel based on SERCOS III provides deterministic cyclic data exchange between drives, which helps support multi-axis synchronization. The controller is delivered with the ADVANCED control section design, which adds onboard motion functions and parameter memory for local setup storage. Thermal management relies on internal air cooling through an integrated blower, eliminating the need for external ductwork. During dynamic peaks, the power stage can deliver up to 9 A of output current, which supports brief acceleration demands on compatible motor sizes. An enclosure rating of IP20 means the device must be installed in a protected cabinet, and the housing provides finger-safe protection rather than sealed dust protection.

The power section accepts a mains supply of 3 × AC 110–230 V ±10%, which suits low-voltage regional grids and standby power sources. Field-level communication is handled by a MultiEthernet port that supports several industrial Ethernet protocols without extra hardware. The integrated supply is classified as Infeeding / Feeded, which allows energy exchange between drives on a shared DC bus. The unit uses design version 1. Encoder feedback from motors is processed through an IndraDyn Hiperface/EnDat 2.1/2.2 channel, and no additional safety interface is installed.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
9 A
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0009A02ACCECETNNNNNW
  • HCS011EW0009A02ACCECETNNNNNW
  • HCS01 1E W0009 A 02 A CC EC ET NN NN NW
  • HCS01 1E W0009 A 02 A CC EC ET NN NN NW
  • #REF!
  • #REF!
  • hcs01.1e-w0008-a-03-b-et-ec-ec-nn-aa-fw
  • hcs01.1e-w0008-a-03-b-et-ec-ec-nn-aa-fw
  • HCS1.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS1.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • hcs01.1e-w0009-a-02-a-cc-ec-et-nn-nn-nw
  • hcs01.1e-w0009-a-02-a-cc-ec-et-nn-nn-nw
  • HCS1.1E-W9-A-2-A-CC-EC-ET-NN-NN-NW
  • HCS1.1E-W9-A-2-A-CC-EC-ET-NN-NN-NW
  • hcs011ew0009a02accecetnnnnnw
  • hcs011ew0009a02accecetnnnnnw
  • HC501.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HC501.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCSO1.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCSO1.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS0I.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS0I.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.IE-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.IE-W0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-WO009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-WO009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0O09-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0O09-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W00O9-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W00O9-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-O2-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-O2-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-0Z-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-0Z-A-CC-EC-ET-NN-NN-NW
  • HC5OI.IE-WOOO9-A-OZ-A-CC-EC-ET-NN-NN-NW
  • HC5OI.IE-WOOO9-A-OZ-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-2-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009-A-2-A-CC-EC-ET-NN-NN-NW
  • HCS01.1EW0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1EW0009-A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1E-W0009A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1EW0009A-02-A-CC-EC-ET-NN-NN-NW
  • HCS01.1EW0009A-02-A-CC-EC-ET-NN-NN-NW

Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW:

Q: What communication interface is supported by the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller?

A: The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW is equipped with a SERCOS III master interface allowing cross communication between devices.

Q: What communication interface is supported by the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller?

A: The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW is equipped with a SERCOS III master interface allowing cross communication between devices.

Q: What cooling method does the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW drive controller use?

A: Cooling for this controller is achieved by internal air using an integrated blower.

Q: What is the peak current rating of the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller?

A: The device operates with a peak current rating of 9 A.

Q: What is the peak current rating of the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller?

A: The device operates with a peak current rating of 9 A.

Q: What is the allowed mains voltage range for the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW?

A: The mains voltage range for this controller is 3 x AC 110 to 230 V with a ±10% tolerance.

Q: What is the allowed mains voltage range for the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW?

A: The mains voltage range for this controller is 3 x AC 110 to 230 V with a ±10% tolerance.

Q: What IP rating does the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller have?

A: This model is designed with an IP20 rating and does not have a safety interface installed.

Q: What IP rating does the HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW controller have?

A: This model is designed with an IP20 rating and does not have a safety interface installed.


Internal Product Review

  • ‘‘The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-NW is a high-performance HCS Drive Controller from Bosch Rexroth Indramat, featuring SERCOS III master cross communication and a MultiEthernet interface for flexible integration. With a peak current rating of 9 A and an ADVANCED control section, this unit is well-suited for demanding automation tasks. Internal air cooling via an integrated blower supports efficient thermal management, making this controller a solid choice for industrial environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo