HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-FW Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R911336678
Ask for AvailabilityThe Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-FW is an HCS IndraDrive Controller equipped with a SERCOS III master communication interface and MultiEthernet connectivity. It uses an internal air cooling method with an integrated blower and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. This unit has a peak device current of 9 Amps and operates at a mains voltage of 3 x AC 110 to 230 Volts with an IP20 rating.
Internal Product Review
The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-FW is an advanced HCS IndraDrive Controller from Bosch Rexroth Indramat, featuring SERCOS III master communication and MultiEthernet support for flexible integration. Internal air cooling through an integrated blower ensures efficient thermal management, while the controller delivers reliable operation at a peak current of 9 A. The IP20 rating and versatile encoder interfaces make it a strong choice for modern automation environments.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-A-CC-EC-ET-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. It regulates servo or induction motors in distributed automation, providing torque, speed, and position control while coordinating with higher-level PLCs. The device belongs to the compact HCS01 line and is supplied as design version 1, which suits installations where cabinet space is limited and low-power motion control is required.
The controller is housed in an IP20 enclosure, so it must be mounted inside a protected cabinet to reduce exposure to dust or liquids. It accepts a three-phase mains supply of 3 x AC 110 to 230 V ±10%, covering typical low-voltage factory networks without an additional transformer. Heat is removed by internal air cooling through an integrated blower, so the fan pulls air across power components to keep semiconductor temperatures within limits. The power stage can supply a peak current of 9 A, enabling short dynamic bursts during acceleration or sudden load changes. For high-resolution feedback, Interface 1 supports the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, giving the drive the position data needed for closed-loop motion.
System communication relies on a SERCOS III master with cross communication port, which synchronizes multiple axes in coordinated motion systems. A secondary port provides MultiEthernet connectivity for networks such as PROFINET and EtherNet/IP. The control section is identified as ADVANCED, which adds extended motion functions for more capable axis control. The power interface is set up for infeeding and fed operation, allowing the controller to share a common DC bus with other drives for energy exchange. The unit does not include integrated safety functions, so external safety hardware is required when the application calls for it.