HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW Bosch Rexroth Indramat
MPN: R911338205
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW is part of the HCS IndraDrive Controllers series and is an HCS drive controller with an IP20 rating and a peak current of 9 Amps. It features an internal air cooling method, SERCOS III master cross communication, and supports MultiEthernet along with encoder interfaces for IndraDyn Hiperface and EnDat 2.1/2.2. The controller operates on a 3-phase AC mains voltage of 110 to 230 Volts and is equipped with an STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Assigned to the HCS01 line, the unit follows design version 1. It serves as the link between a three-phase mains supply and synchronous servomotors, regulating current, speed, and position in automated cells. This arrangement lets the controller convert command data into controlled electrical output for servo-driven axes that require repeatable motion. By combining power electronics with a detachable control section, it supports compact cabinet layouts in material handling, packaging, and general motion systems.
The controller exchanges cyclic setpoints over a SERCOS III master (cross communication) bus, allowing coordinated motion across multiple axes. During acceleration bursts, it can deliver up to 9 A of peak output for short periods. That short-term current capacity helps the axis respond to changing load demands during indexing and start-stop movement. An IP20 housing is touch-safe but requires installation inside a closed control cabinet. Its supply range of 3 x AC 110...230 V ±10% allows operation on common low-voltage factory networks. For safety, the integrated STO (Safe Torque Off) interface removes motor torque through hardware circuits.
The paired control section is classified as ADVANCED, which adds extended motion functions and parameter memory. This gives the drive broader control capability than a basic control section. Thermal management uses internal air cooling through an integrated blower, so external ducting is not required and cabinet air moves across the heat sink. Encoder feedback is handled by the universal Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, allowing connection to compatible motor feedback systems. A separate MultiEthernet interface supports diagnostic and network communication over several Ethernet-based protocols.
Frequently Asked Questions about HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW IndraDrive Controller use?
A: The HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW supports SERCOS III master cross communication for integration with advanced automation networks.
Q: How is the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW cooled?
A: This drive controller features an internal air cooling method using an integrated blower for thermal management.
Q: What is the peak current rating of the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW?
A: The maximum device peak current for this controller is 9 A.
Q: What is the mains voltage requirement for the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW controller?
A: This controller operates on a mains voltage of 3 x AC 110...230 V ±10%.
Q: What type of safety interface is included with the HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW controller?
A: The HCS01.1E-W0009-A-02-A-CC-EC-ET-L3-NN-FW offers a Safe Torque Off (STO) safety interface.