4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW Bosch Rexroth Indramat

MPN: R911345134

No Tariffs On US Orders
  • Rated 4.3 (41 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master interface with cross communication and a PROFIBUS interface, and uses an internal air cooling method with an integrated blower. The device supports a peak current of 6 Amps and operates at a mains voltage of 3 x AC 110 to 230 Volts with an IP20 rating.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW belongs to the HCS IndraDrive Controllers series produced by Bosch Rexroth Indramat. As an HCS drive controller, it manages servo and spindle axes in compact automation cabinets, supplying power, signal conditioning, and safety interlocks for IndraDyn motors. Within an installation, it works with a matching control section to close current, speed, and position loops, allowing coordinated motion sequences on conveyors, pick-and-place units, and light machine tools.

The power stage accepts a three-phase mains input of 3 x AC 110...230 V ±10% and can deliver up to 6 A of peak output current to the connected motor windings. Thermal loads are removed by internal air cooling through an integrated blower, so no external cooling ducts are required in cabinets with typical plant airflow. An IP20 housing limits accidental contact with energized parts while keeping the unit compact for cabinet installation. The unit is design version 1. Power is drawn from the DC bus of an infeeding or fed-back supply module, enabling common-bus energy sharing among multiple axes.

For real-time networking, the controller offers a SERCOS III master with cross communication channel that synchronizes distributed drives with very precise timing. The paired control section is classified as ADVANCED, adding onboard PLC resources and safety functions without external cards. Motor feedback is routed through the multifunction sensor port, which supports IndraDyn Hiperface or EnDat 2.1/2.2 encoder feedback, while field-level commands from PLCs can also arrive over PROFIBUS. This combination of motion networking, encoder support, and fieldbus connectivity allows the controller to fit into both newer IndraMotion systems and existing production lines without extra gateway hardware.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • hcs011ew0006a02accecpbs4nnfw
  • HCS011EW0006A02ACCECPBS4NNFW
  • HC501.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01 1E W0006 A 02 A CC EC PB S4 NN FW
  • HCSO1.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • #REF!
  • HCS0I.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • hcs01.1e-w0005-a-03-b-et-ec-cn-l3-nn-fw
  • HCS01.IE-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS1.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-WO006-A-02-A-CC-EC-PB-S4-NN-FW
  • hcs01.1e-w0006-a-02-a-cc-ec-pb-s4-nn-fw
  • HCS01.1E-W0O06-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS1.1E-W6-A-2-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W00O6-A-02-A-CC-EC-PB-S4-NN-FW
  • hcs011ew0006a02accecpbs4nnfw
  • HCS01.1E-W000G-A-02-A-CC-EC-PB-S4-NN-FW
  • HC501.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-O2-A-CC-EC-PB-S4-NN-FW
  • HCSO1.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-0Z-A-CC-EC-PB-S4-NN-FW
  • HCS0I.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-P8-S4-NN-FW
  • HCS01.IE-W0006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-PB-54-NN-FW
  • HCS01.1E-WO006-A-02-A-CC-EC-PB-S4-NN-FW
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-P8-54-NN-FW
  • HCS01.1E-W0O06-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W00O6-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-2-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W000G-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-O2-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-0Z-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-P8-S4-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-PB-54-NN-FW
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-P8-54-NN-FW
  • HCS01.1E-W006-A-02-A-CC-EC-PB-S4-NN-FW
  • HCS01.1E-W0006-A-2-A-CC-EC-PB-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW:

Q: What is the peak current rating for the HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW drive controller?

A: The HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW offers a device peak current of 6 A for operational demands.

Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW cooled during operation?

A: This model uses internal air cooling through an integrated blower to regulate its temperature.

Q: What communication interface does the HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW use?

A: A SERCOS III master (cross communication) is provided as the main communication interface on this controller.

Q: What is the supported mains voltage range for the HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW controller?

A: The HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW supports a mains voltage of 3 x AC 110 to 230 V ±10%.

Q: What level of ingress protection (IP rating) does the HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW have?

A: This drive controller is classified as IP20, providing basic protection against large solid foreign objects.


Internal Product Review

  • ‘‘The HCS01.1E-W0006-A-02-A-CC-EC-PB-S4-NN-FW is an HCS IndraDrive Controller by Bosch Rexroth Indramat, featuring a SERCOS III master interface with cross communication and PROFIBUS support. The unit offers 6 A peak current and operates on a 3 x AC 110–230 V ±10% mains voltage, making it well-suited for advanced motion control tasks. Internal air cooling with an integrated blower ensures efficient thermal management for reliable operation.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo