4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW Bosch Rexroth Indramat

MPN: R911370440

No Tariffs On US Orders
  • Rated 4.5 (63 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It uses a SERCOS III master communication interface with cross communication and supports an IndraDyn Hiperface or EnDat encoder interface. This controller features an internal air cooling system with integrated blower and has an IP20 rating along with a peak device current of 6 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW is a compact drive controller manufactured by Bosch Rexroth Indramat as part of the HCS IndraDrive Controllers series. It acts as the power and control interface for servo and induction motors, converting mains power and issuing precise current commands so that industrial axes follow programmed velocity and position profiles. Integrated logic and fieldbus connectivity allow this controller to coordinate with PLCs and safety modules, making it suitable for material-handling systems, pick-and-place stations, and other motion-centric automation.

The controller communicates over a SERCOS III master (cross communication) channel, providing deterministic timing for multi-axis synchronization. Internally it uses the ADVANCED control section, adding extended motion functions and parameter memory to the base hardware. Thermal management is handled by internal air cooling through an integrated blower, so the blower pushes cabinet air across the heat sink and no external ducting is required. A device peak output of 6 A supports low-to-medium power motors during acceleration events without exceeding semiconductor limits. Its housing is rated IP20, indicating finger protection but requiring installation in a closed electrical enclosure.

Electrical input is accepted from 3 × AC 110 to 230 V ±10%, matching three-phase supplies common in light industrial panels. Feedback is processed through a dedicated encoder port that supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder feedback. A second interface slot is present but not populated, simplifying wiring when only one sensor loop is required. The drive belongs to the HCS01 line and uses an infeeding/fed power supply concept, allowing it to share a common DC bus with other IndraDrive units. Design version 1 and the lack of extra mechanical options keep dimensions and weight minimal for dense cabinet layouts.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0006A02ACCECNNS4NNFW
  • HCS011EW0006A02ACCECNNS4NNFW
  • HCS01 1E W0006 A 02 A CC EC NN S4 NN FW
  • HCS01 1E W0006 A 02 A CC EC NN S4 NN FW
  • #REF!
  • #REF!
  • hcs01.1e-w0005-a-03-a-et-ec-nn-l4-nn-fw
  • hcs01.1e-w0005-a-03-a-et-ec-nn-l4-nn-fw
  • HCS1.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS1.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • hcs01.1e-w0006-a-02-a-cc-ec-nn-s4-nn-fw
  • hcs01.1e-w0006-a-02-a-cc-ec-nn-s4-nn-fw
  • HCS1.1E-W6-A-2-A-CC-EC-NN-S4-NN-FW
  • HCS1.1E-W6-A-2-A-CC-EC-NN-S4-NN-FW
  • hcs011ew0006a02accecnns4nnfw
  • hcs011ew0006a02accecnns4nnfw
  • HC501.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HC501.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCSO1.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCSO1.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS0I.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS0I.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.IE-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.IE-W0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-WO006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-WO006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0O06-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0O06-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W00O6-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W00O6-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W000G-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W000G-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-O2-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-O2-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-0Z-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-0Z-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-NN-54-NN-FW
  • HCS01.1E-W0006-A-02-A-CC-EC-NN-54-NN-FW
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-NN-54-NN-FW
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-NN-54-NN-FW
  • HCS01.1E-W006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-2-A-CC-EC-NN-S4-NN-FW
  • HCS01.1E-W0006-A-2-A-CC-EC-NN-S4-NN-FW
  • HCS01.1EW0006-A-02-A-CC-EC-NN-S4-NN-FW
  • HCS01.1EW0006-A-02-A-CC-EC-NN-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW:

Q: What type of communication interface is included on the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW controller?

A: This controller uses the SERCOS III master communication interface for cross communication.

Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW controller cooled?

A: The cooling method for this model is internal air through an integrated blower.

Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW controller cooled?

A: The cooling method for this model is internal air through an integrated blower.

Q: What is the peak current capacity of the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW?

A: The device is rated for a peak current of 6 A.

Q: What is the peak current capacity of the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW?

A: The device is rated for a peak current of 6 A.

Q: What mains voltage range does the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW support?

A: This controller accepts a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.

Q: What mains voltage range does the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW support?

A: This controller accepts a mains voltage of 3 x AC 110 to 230 V with a ±10% tolerance.

Q: What is the IP rating for the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW controller?

A: The protection rating for this drive controller is IP20.

Q: What is the IP rating for the HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW controller?

A: The protection rating for this drive controller is IP20.


Internal Product Review

  • ‘‘The HCS01.1E-W0006-A-02-A-CC-EC-NN-S4-NN-FW is a drive controller from the HCS IndraDrive series by Bosch Rexroth Indramat, featuring an ADVANCED control section and SERCOS III master communication interface. Internal air cooling with an integrated blower and a peak current of 6 A make it suitable for stable operation in demanding environments. The IP20 rating further ensures reliable protection for industrial applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo