4.95 based on 202 reviews

🙶 Excellent to work with and they stand behind their work. I would highly recommend them. 🙷

HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW Bosch Rexroth Indramat

MPN: R911339697

No Tariffs On US Orders
  • Rated 4.5 (80 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface with cross communication and supports mains voltage of 3 x AC 110 to 230 V. This controller uses air cooling with an integrated blower, has a peak current of 6 Amps, and is equipped with an IP20 rating and an STO safety interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The device governs servo or induction axes in industrial automation, converting incoming line power to regulated motor current while executing motion commands received from higher-level PLCs. By combining power electronics, feedback processing, and safety circuitry in one housing, it forms a compact node for tasks such as positioning, speed control, and coordinated multi-axis interpolation. This arrangement supports machine sections that require responsive axis behavior without adding a large control footprint inside the cabinet.

It operates from a three-phase mains supply of 3 × AC 110…230 V ±10%, allowing direct connection to low-voltage factory networks. The drive delivers a peak output of 6 A, supplying short-term torque during acceleration or rapid index moves. Heat is removed through internal air cooling through an integrated blower, so external ducting is unnecessary and panel layouts remain compact. An enclosure rating of IP20 confines installation to closed cabinets but still allows straightforward access to wiring and adjacent control components. Functional safety is provided by the STO (Safe Torque Off) channel, which disables motor power rapidly without shutting down the complete automation cell.

The control platform communicates via a SERCOS III master, enabling deterministic cross-communication and time-synchronized motion between multiple drives. Its control section uses the ADVANCED variant, which supports coordinated motion functions for demanding automation tasks. Because the power stage is classified as infeeding and fed, the unit can return excess energy to a shared DC bus or draw power from it as required by the axis. Motor feedback connects through the dedicated Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, and the second feedback position is left unpopulated. This layout keeps the configured hardware focused on the primary feedback channel while maintaining clear integration with compatible motor systems.

Communication Interface
SERCOS III master (cross communication)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
6 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
STO (Safe Torque Off)
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-NN-L3-NN-FW
  • HCS011EW0006A02ACCECNNL3NNFW
  • HCS01.1E-W006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01 1E W0006 A 02 A CC EC NN L3 NN FW
  • HCS01.1E-W0006-A-2-A-CC-EC-NN-L3-NN-FW
  • #REF!
  • HCS01.1EW0006-A-02-A-CC-EC-NN-L3-NN-FW
  • hcs01.1e-w0005-a-03-a-et-ec-da-nn-nn-fw
  • HCS01.1E-W0006A-02-A-CC-EC-NN-L3-NN-FW
  • HCS1.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW
  • hcs01.1e-w0006-a-02-a-cc-ec-nn-l3-nn-fw
  • HCS1.1E-W6-A-2-A-CC-EC-NN-L3-NN-FW
  • hcs011ew0006a02accecnnl3nnfw
  • HC501.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCSO1.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS0I.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.IE-W0006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-WO006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W0O06-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W00O6-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W000G-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W0006-A-O2-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W0006-A-0Z-A-CC-EC-NN-L3-NN-FW
  • HC5OI.IE-WOOOG-A-OZ-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W0006-A-2-A-CC-EC-NN-L3-NN-FW
  • HCS01.1EW0006-A-02-A-CC-EC-NN-L3-NN-FW
  • HCS01.1E-W0006A-02-A-CC-EC-NN-L3-NN-FW

Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW:

Q: What communication interface does the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW controller support?

A: The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW offers SERCOS III master interface for cross communication.

Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW cooled?

A: This controller is designed with an integrated blower for internal air cooling.

Q: What is the peak current rating for the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW?

A: The device supports a peak current of 6 A.

Q: What mains voltage range can the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW operate on?

A: The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is rated for use with 3-phase AC 110 to 230 V ±10%.

Q: What type of safety interface does the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW have?

A: The safety interface provided on this controller is STO, which stands for Safe Torque Off.


Internal Product Review

  • ‘‘The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is an HCS IndraDrive Controller from Bosch Rexroth Indramat featuring an advanced control section and an integrated internal air blower for efficient cooling. With a SERCOS III master interface and an IP20 rating, this controller is well-suited for modern automation environments. Safe Torque Off (STO) functionality adds an important layer of operational safety.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo