HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW Bosch Rexroth Indramat
MPN: R911339697
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features a SERCOS III master communication interface with cross communication and supports mains voltage of 3 x AC 110 to 230 V. This controller uses air cooling with an integrated blower, has a peak current of 6 Amps, and is equipped with an IP20 rating and an STO safety interface.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is a drive controller produced by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. The device governs servo or induction axes in industrial automation, converting incoming line power to regulated motor current while executing motion commands received from higher-level PLCs. By combining power electronics, feedback processing, and safety circuitry in one housing, it forms a compact node for tasks such as positioning, speed control, and coordinated multi-axis interpolation. This arrangement supports machine sections that require responsive axis behavior without adding a large control footprint inside the cabinet.
It operates from a three-phase mains supply of 3 × AC 110…230 V ±10%, allowing direct connection to low-voltage factory networks. The drive delivers a peak output of 6 A, supplying short-term torque during acceleration or rapid index moves. Heat is removed through internal air cooling through an integrated blower, so external ducting is unnecessary and panel layouts remain compact. An enclosure rating of IP20 confines installation to closed cabinets but still allows straightforward access to wiring and adjacent control components. Functional safety is provided by the STO (Safe Torque Off) channel, which disables motor power rapidly without shutting down the complete automation cell.
The control platform communicates via a SERCOS III master, enabling deterministic cross-communication and time-synchronized motion between multiple drives. Its control section uses the ADVANCED variant, which supports coordinated motion functions for demanding automation tasks. Because the power stage is classified as infeeding and fed, the unit can return excess energy to a shared DC bus or draw power from it as required by the axis. Motor feedback connects through the dedicated Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, and the second feedback position is left unpopulated. This layout keeps the configured hardware focused on the primary feedback channel while maintaining clear integration with compatible motor systems.
Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW controller support?
A: The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW offers SERCOS III master interface for cross communication.
Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW cooled?
A: This controller is designed with an integrated blower for internal air cooling.
Q: What is the peak current rating for the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW?
A: The device supports a peak current of 6 A.
Q: What mains voltage range can the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW operate on?
A: The HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW is rated for use with 3-phase AC 110 to 230 V ±10%.
Q: What type of safety interface does the HCS01.1E-W0006-A-02-A-CC-EC-NN-L3-NN-FW have?
A: The safety interface provided on this controller is STO, which stands for Safe Torque Off.