HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW Bosch Rexroth Indramat
MPN: R911338045
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW is an HCS Drive Controller in the HCS IndraDrive Controllers series. It features an ADVANCED control section, device peak current of 6 A, and a SERCOS III master communication interface. The controller uses air cooling with an integrated blower and has IP20 protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW is an HCS Drive Controller manufactured by Bosch Rexroth Indramat within the HCS IndraDrive Controllers series. Installed as the power and control center for servo and induction motors, it regulates torque and speed to coordinate motion axes in industrial automation cells. The unit houses both a power section and a detachable control section, allowing the control hardware to be matched to the application without rewiring the power stage. When combined with compatible Rexroth motors, it forms a closed-loop drive package for packaging machines, printing lines, and material-handling systems.
The power section accepts a three-phase supply of 3 x AC 110...230 V ±10% and can deliver up to 6 A peak current to the connected motor. Heat generated by the switching devices is moved out of the housing by internal air cooling created by an integrated blower, allowing rated operation without external ducts. The housing carries an IP20 rating, so the unit must be installed inside a closed electrical cabinet. Drive shutdown for functional safety is implemented through a single-channel STO interface, which removes torque-forming pulses while preserving encoder position data. The power supply section supports both infeeding and fed operation, enabling common DC bus configurations.
The control card manages motion profiles and diagnostics. Its design level is identified as ADVANCED, and it couples to the power section through coded connectors referenced in the pairing note. Real-time fieldbus exchange with controllers is possible over SERCOS III master cross-communication, while auxiliary PLC networks can run simultaneously on MultiEthernet ports. Feedback from motors is processed through an IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface, enabling high-resolution position control. The device is design version 1.
Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW:
Q: What communication interface does the HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW controller utilize?
A: The HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW supports SERCOS III master cross communication for advanced networking capabilities.
Q: How is the HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW cooled?
A: This drive controller uses an internal air-cooling method provided by an integrated blower for thermal management.
Q: What is the mains voltage requirement for the HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW?
A: It is designed to operate on a mains voltage supply of 3 x AC 110 to 230 V with ±10% tolerance.
Q: What is the device peak current for the HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW?
A: The device supports a peak current of 6 A for demanding drive applications.
Q: What safety interface is included on the HCS01.1E-W0006-A-02-A-CC-EC-ET-L3-NN-FW?
A: This model features a Safe Torque Off (STO) safety interface for enhanced operational safety.