HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW Bosch Rexroth Indramat
MPN: R911341617
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW is an HCS Drive Controller from the HCS IndraDrive Controllers series. It features an ADVANCED control section design, supports SERCOS III master cross communication, and has a device peak current of 6 Amps. This controller uses air cooling through an integrated blower and provides both STO and SBC safety interfaces.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW drive controller is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series and belongs to the compact HCS01 line. Used inside automated machinery, it bridges the three-phase mains supply, communication networks, and motor power stage so that torque, speed, and position commands can be carried out with millisecond accuracy in production cells. Its compact format suits cabinet installations where control, power conversion, and network connectivity need to be combined in a limited amount of space.
This controller accepts a supply of 3 x AC 110...230 V ±10% and can deliver up to 6 A of peak output current. Protection against accidental contact with live parts is provided by the IP20 housing, and thermal energy is removed by an internal air blower. Functional safety is integrated through STO and SBC, enabling immediate torque shutdown and brake control without external relays. Real-time axis coordination is handled over a SERCOS III master interface that supports cross communication between drives. The device is shipped as design version 1 and carries no additional optional hardware.
The control section installed in this unit is the ADVANCED type specified for the model, and it mates electrically with a power module that can operate in either infeeding or fed mode to recycle or draw energy as required. Position feedback is connected through the multifunctional Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port, while auxiliary I/O and diagnostics are handled over CANopen. The ADVANCED control section is factory matched to the base hardware, which helps preserve consistent electrical behavior during startup and operation. No additional option cards are included, so the listed interfaces remain the key connections that must be planned in the cabinet layout.
Frequently Asked Questions about HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW:
Q: What communication interface does the HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW drive controller use?
A: The HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW controller communicates using a SERCOS III master interface with cross communication capabilities.
Q: What cooling method is employed in the HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW model?
A: This controller uses internal air cooling provided by an integrated blower.
Q: What is the peak current rating for the HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW controller?
A: The device supports a peak current of 6 A during operation.
Q: Which safety interfaces are available on the HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW?
A: This controller is equipped with STO (Safe Torque Off) and SBC (Safe Brake Control) safety functions.
Q: What is the mains voltage requirement for the HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW drive controller?
A: The HCS01.1E-W0006-A-02-A-CC-EC-CN-L4-NN-FW operates on a mains voltage of 3 x AC 110...230 V ±10%.