HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW Bosch Rexroth Indramat
MPN: R911331032
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW is part of the HCS IndraDrive Controllers series and features a SERCOS III communication interface. This HCS Drive Controller has a device peak current of 5 Amps, operates at a mains voltage of 3 x AC 200 to 500 Volts, and is air-cooled via an integrated blower. It comes in an ECOnomy design type and has an IP20 rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW is produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It functions as a drive controller for small- to mid-power servo axes, supplying regulated DC-link energy to connected motors and exchanging motion commands with a higher-level PLC over factory networks. By combining power electronics, control logic, and diagnostic functions in one housing, the unit supports compact axis integration in automated assembly cells, packaging machines, and material-handling stations. This arrangement keeps motor regulation, status monitoring, and fault handling inside a single drive platform.
The power section operates from a three-phase mains supply of 3 x AC 200…500 V ±10% and can deliver a peak current of 5 A during short acceleration periods. Heat generated by the switching stage is removed through internal air cooling, which uses an integrated blower to move cabinet air across the heatsink. The controller communicates with the automation layer through SERCOS III, providing deterministic real-time exchange of setpoints, actual values, and status data for coordinated motion tasks. Protection is limited to IP20, so the unit is intended for installation inside an electrical enclosure rather than for exposed mounting. That enclosure-based arrangement helps shield the drive from accidental contact and ordinary contamination in industrial cabinets.
The mounted control section uses the ECONOMY design and is identified as Design Version 1. Position feedback is processed through the multi-protocol Encoder IndraDyn Hiperface/EnDat 2.1/2.2 interface, allowing compatibility with several common motor feedback systems used in the IndraDrive platform. A second feedback port and the safety interface are not equipped, which keeps the hardware configuration straightforward for applications that do not require those options. The energy path is classified as Infeeding / Feeded, allowing the controller to operate within a common DC-bus arrangement used by related drives in the cabinet. This setup is suitable for installations where several axes are grouped in one enclosure and supplied through a coordinated power structure.
Frequently Asked Questions about HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW:
Q: What communication interface is available on the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW?
A: This drive controller uses SERCOS III for its primary communication interface.
Q: What communication interface is available on the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW?
A: This drive controller uses SERCOS III for its primary communication interface.
Q: What input voltage does the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW require?
A: The device supports a mains voltage range of 3 x AC 200 to 500 V with a ±10% tolerance.
Q: What input voltage does the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW require?
A: The device supports a mains voltage range of 3 x AC 200 to 500 V with a ±10% tolerance.
Q: What control section design type does this drive controller feature?
A: HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW is an ECONOMY design control section version.
Q: What control section design type does this drive controller feature?
A: HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW is an ECONOMY design control section version.
Q: What cooling method is used for the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW?
A: This drive controller is cooled internally using an integrated air blower.
Q: What cooling method is used for the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW?
A: This drive controller is cooled internally using an integrated air blower.
Q: What is the peak current capability of the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW drive controller?
A: The peak current supported by this model is 5 A.
Q: What is the peak current capability of the HCS01.1E-W0005-A-03-E-S3-EC-NN-NN-AA-FW drive controller?
A: The peak current supported by this model is 5 A.