4.95 based on 202 reviews

🙶 I have always received exceptional service and support in my many years of working with Wake Industrial. 🙷

HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW Bosch Rexroth Indramat

MPN: R911387472

No Tariffs On US Orders
  • Rated 4.5 (66 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW is a drive controller from the HCS IndraDrive Controllers series designed with a BASIC control section. It has a device peak current of 5 Amps and an IP20 rating. This unit uses an internal air cooling method with an integrated blower and features a MultiEthernet communication interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW is a drive controller produced by Bosch Rexroth Indramat for the HCS IndraDrive Controllers series. It is intended to regulate servo and synchronous motors in modular automation stations, linking the motion section to higher-level PLCs over plant networks. By combining the power section and a detachable control section in one housing, the unit supplies regulated current to the motor while collecting feedback for closed-loop positioning and speed control. This arrangement helps keep the drive package compact in multi-axis installations where cabinet space is limited. It is suited to machine sections that need compact axis control without separating the inverter from the controller.

This controller exchanges process data over a MultiEthernet interface, so a single hardware port can be configured for several industrial Ethernet protocols. Its three-phase input accepts 200–500 VAC with a tolerance of ±10 percent, allowing the same model to operate on a wide range of plant power systems without tap changes. The power stage can deliver up to 5 A of peak current to the connected motor, which supports short acceleration demands before the load returns to normal running levels. An IP20 housing protects live parts and requires installation inside a control cabinet. Thermal management relies on internal air cooling through an integrated blower, so no external heat sink or ducting is required.

The control section supplied with this inverter is the BASIC variant, and it handles rotor feedback through the IndraDyn Hiperface/EnDat 2.1/2.2 encoder interface for precise position evaluation. This allows the drive to work with common feedback arrangements used on compatible motors. DC bus energy is managed by an infeeding power module, enabling shared power among several axes on the same rail. The unit is identified as design version 1, indicating the hardware generation used for this controller.

Communication Interface
MultiEthernet
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
5 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
  • HCS011EW0005A03BETECEPS4NNFW
  • HCS011EW0005A03BETECEPS4NNFW
  • HCS01 1E W0005 A 03 B ET EC EP S4 NN FW
  • HCS01 1E W0005 A 03 B ET EC EP S4 NN FW
  • #REF!
  • #REF!
  • hcs01.1e-w0003-a-02-b-et-ec-ep-nn-nn-fw
  • hcs01.1e-w0003-a-02-b-et-ec-ep-nn-nn-fw
  • HCS1.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS1.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • hcs01.1e-w0005-a-03-b-et-ec-ep-s4-nn-fw
  • hcs01.1e-w0005-a-03-b-et-ec-ep-s4-nn-fw
  • HCS1.1E-W5-A-3-B-ET-EC-EP-S4-NN-FW
  • HCS1.1E-W5-A-3-B-ET-EC-EP-S4-NN-FW
  • hcs011ew0005a03beteceps4nnfw
  • hcs011ew0005a03beteceps4nnfw
  • HC501.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HC501.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCSO1.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCSO1.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS0I.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS0I.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.IE-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.IE-W0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-WO005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-WO005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0O05-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0O05-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W00O5-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W00O5-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W000S-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W000S-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-O3-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-O3-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-03-8-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-03-8-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-03-B-ET-EC-EP-54-NN-FW
  • HCS01.1E-W0005-A-03-B-ET-EC-EP-54-NN-FW
  • HC5OI.IE-WOOOS-A-O3-8-ET-EC-EP-54-NN-FW
  • HC5OI.IE-WOOOS-A-O3-8-ET-EC-EP-54-NN-FW
  • HCS01.1E-W005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-3-B-ET-EC-EP-S4-NN-FW
  • HCS01.1E-W0005-A-3-B-ET-EC-EP-S4-NN-FW
  • HCS01.1EW0005-A-03-B-ET-EC-EP-S4-NN-FW
  • HCS01.1EW0005-A-03-B-ET-EC-EP-S4-NN-FW

Frequently Asked Questions about HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW:

Q: What type of communication interface is available on the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW drive controller?

A: The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW features a MultiEthernet communication interface for diverse connectivity options.

Q: What type of communication interface is available on the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW drive controller?

A: The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW features a MultiEthernet communication interface for diverse connectivity options.

Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW cooled during operation?

A: This drive controller utilizes an integrated blower for internal air cooling.

Q: How is the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW cooled during operation?

A: This drive controller utilizes an integrated blower for internal air cooling.

Q: What is the peak current capacity of the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW controller?

A: The device supports a peak current of 5 A, suitable for various industrial application needs.

Q: What is the peak current capacity of the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW controller?

A: The device supports a peak current of 5 A, suitable for various industrial application needs.

Q: What mains voltage range does the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW support?

A: This model operates with a mains voltage input of 3 x AC 200 to 500 V ±10%.

Q: What mains voltage range does the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW support?

A: This model operates with a mains voltage input of 3 x AC 200 to 500 V ±10%.

Q: Which encoder interfaces are supported by the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW?

A: The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW utilizes encoder feedback interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.

Q: Which encoder interfaces are supported by the HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW?

A: The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW utilizes encoder feedback interfaces compatible with IndraDyn Hiperface and EnDat 2.1/2.2.


Internal Product Review

  • ‘‘The HCS01.1E-W0005-A-03-B-ET-EC-EP-S4-NN-FW is an HCS IndraDrive Controller from Bosch Rexroth Indramat, featuring MultiEthernet communication and a BASIC control section for user-friendly integration. With an internal air cooling system and device peak current of 5 A, this model is well-suited for compact drive solutions. Its IP20 rating and compatibility with IndraDyn Hiperface/EnDat 2.1/2.2 encoders make it a solid choice for modern automation environments.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo