4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW Bosch Rexroth Indramat

MPN: R911328423

No Tariffs On US Orders
  • Rated 4.5 (84 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW is a drive controller from the HCS IndraDrive Controllers series. It features a SERCOS III communication interface and supports encoder interfaces such as IndraDyn Hiperface and EnDat 2.1/2.2. This controller offers an internal air cooling method with an integrated blower and has a device peak current of 3 Amps.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW is a drive controller manufactured by Bosch Rexroth Indramat and part of the HCS IndraDrive Controllers series. In multi-axis machining centers, packaging lines, and material-handling systems, it regulates inverter output so connected servo motors follow commanded speed and torque profiles with the accuracy required for closed-loop automation. It is suited for coordinated axes that must maintain repeatable motion during indexing, positioning, and speed-regulated transport tasks. Closed-loop control helps the connected motor respond consistently when load conditions change during operation.

Communication is handled over SERCOS III, which supports deterministic data exchange with higher-level controls and neighboring drives. The unit accepts a mains input of 3 x AC 110 to 230 V ±10% and can deliver a device peak current of 3 A for short acceleration demands. Heat is removed by internal air cooling through an integrated blower, and the housing is rated IP20 for installation in protected control cabinets. Because the enclosure is intended for cabinet use, the controller should not be mounted on exposed machine surfaces. No integrated safety interface is included, so any required safety functions must be provided by external equipment, and Interface 2 is not equipped.

The control section uses the ECONOMY design and belongs to the HCS01 line. Motor feedback is processed through IndraDyn Hiperface or EnDat 2.1/2.2 encoder feedback, allowing high-resolution position data for precise vector control and stable motor commutation. The power supply concept supports infeeding and fed operation, so the module can receive DC bus energy from a shared supply or serve as an infeed unit. This version is design version 1, so wiring and control assignments follow that revision.

Communication Interface
SERCOS III
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
Design Version
1
Device Peak Current
3 A
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
IP Rating
IP20
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Other Design Features
None
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Safety Interface
Not equipped
  • HCS011EW0003A02ES3ECNNNNNNFW
  • HCS01 1E W0003 A 02 E S3 EC NN NN NN FW
  • #REF!
  • hcs04.2e-w1240-n-04-dnnn
  • HCS1.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW
  • hcs01.1e-w0003-a-02-e-s3-ec-nn-nn-nn-fw
  • HCS1.1E-W3-A-2-E-S3-EC-NN-NN-NN-FW
  • hcs011ew0003a02es3ecnnnnnnfw
  • HC501.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCSO1.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS0I.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.IE-W0003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-WO003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0O03-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W00O3-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0003-A-O2-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0003-A-0Z-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0003-A-02-E-53-EC-NN-NN-NN-FW
  • HC5OI.IE-WOOO3-A-OZ-E-53-EC-NN-NN-NN-FW
  • HCS01.1E-W003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0003-A-2-E-S3-EC-NN-NN-NN-FW
  • HCS01.1EW0003-A-02-E-S3-EC-NN-NN-NN-FW
  • HCS01.1E-W0003A-02-E-S3-EC-NN-NN-NN-FW

Frequently Asked Questions about HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW:

Q: What communication interface is provided on the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW?

A: This model uses SERCOS III for its communication interface.

Q: What type of encoder interfaces are available on the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW?

A: The drive supports encoder feedback through IndraDyn Hiperface and EnDat 2.1/2.2 interfaces.

Q: How is the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW cooled during use?

A: Cooling is achieved internally using an integrated blower for efficient operation.

Q: What is the peak current rating of the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW?

A: The device peak current supported by this controller is 3 A.

Q: What mains voltage range is the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW compatible with?

A: This unit is designed for use with three-phase AC mains voltage ranging from 110 to 230 V ±10%.


Internal Product Review

  • ‘‘The HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-NN-FW is a compact drive controller from Bosch Rexroth Indramat's HCS IndraDrive series, featuring SERCOS III communication and ECONOMY control section design. With an integrated internal air blower for cooling and IP20 protection, this unit offers efficient and reliable operation in industrial environments. Its 3 A peak current capability makes it well-suited for light to moderate motion control applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo