FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 Bosch Rexroth Indramat
MPN: R912004676
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
4 Minutes
36 Seconds
The Bosch Rexroth Indramat FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 is a frequency converter from the FVCA Frequency Converters series. It delivers an output power of 22.0 kW, operates at a nominal voltage of 400 V, and handles a rated input current of 53.0 A. Featuring PID control, an LCD display, and support for ModBus communication, it has a protection rating of IP20 and weighs 16.5 kg.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 belongs to the FVCA Frequency Converters series produced by Bosch Rexroth Indramat. It is a cabinet-mounted frequency converter that modulates three-phase mains power so induction or synchronous motors can be driven at variable speeds in automated lines, conveyors, and pump systems. The unit combines scalar control with an internal PID regulator and stores its operating logic in the standard full-version firmware, making it a self-contained component for closed-loop speed or pressure regulation tasks.
This converter accepts a nominal input of 400 V and delivers a motor output rating of 22.0 kW when operated within its three-phase 380 to 480 V input window. Under rated load, the inverter supplies 44.0 A of output current while synthesizing motor voltage with space-vector PWM; switching occurs at a default carrier frequency of 6.0 kHz, a value chosen to balance acoustic noise and switching losses. Speed command resolution is 0.01 Hz, and the inverter can raise output frequency to 400 Hz so high-speed spindles or centrifugal machines can run without a mechanical gear change. Modbus communication through the front LCD panel enables remote parameter changes, diagnostic queries, and data logging over standard fieldbus links.
The overload envelope is 200 % In for 1 s; 150 % In for 60 s, allowing short bursts of excess torque during startup or rapid acceleration without triggering protective trips. The converter carries an apparent power rating of 30.0 kVA, so upstream circuit breakers and cabling can be sized accurately. An IP20 housing provides basic finger protection for installations inside closed electrical panels, and cabinet layout must account for its 16.5 kg mass when selecting rail or back-plate support. External braking resistors can be added to the integrated chopper to dissipate regenerated energy when decelerating large-inertia loads at the 1:1000 encoder-assisted speed range.
Frequently Asked Questions about FVCA01.1-22K0-3P4-MDA-LP-P002-01V01:
Q: What is the maximum output power of the FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 frequency converter?
A: The FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 supports a maximum output power of 22.0 kW for demanding motor applications.
Q: What is the supported input voltage range for the FVCA01.1-22K0-3P4-MDA-LP-P002-01V01?
A: This frequency converter can operate with a nominal voltage of 400 V and accepts a 3-phase AC supply within a 380 V to 480 V range, with -15% to +10% tolerance.
Q: What type of display does the FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 frequency converter use?
A: The FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 features an LCD display for settings and status viewing.
Q: Does the FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 include an internal brake chopper?
A: To use the internal brake chopper, this model requires an external resistor for braking operations.
Q: What communication interface does the FVCA01.1-22K0-3P4-MDA-LP-P002-01V01 support?
A: Communication with control systems is enabled using the ModBus interface on this model.