FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 Bosch Rexroth Indramat

MPN: R912002615

No Tariffs On US Orders
  • Rated 4.6 (61 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 belongs to the FVCA Frequency Converters series and delivers an apparent power of 21.0 kVA with an output power of 15.0 kW. This frequency converter operates at a nominal voltage of 400 V, with a rated input current of 46.0 A and a rated output current of 33.0 A. It features a ModBus communication interface, integrated brake chopper, and an LCD display, and is protected to IP20 with an operating temperature range of -10 to +40 °C.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 is a frequency converter produced by Bosch Rexroth Indramat for the FVCA Frequency Converters series. Installed between the mains and an AC motor, it generates the variable frequency and voltage needed for precise speed regulation in automated conveyors, pumps, and process drives. The unit fits three-phase industrial networks and supports either closed-loop or open-loop motor control, depending on system requirements.

Electrical capacity includes 15.0 kW of mechanical output from a DC bus based on a nominal input of 400 V. The inverter supplies 33.0 A continuously to the motor across a programmable range of 0 to 400 Hz, enabling broad speed coverage. Short-term overload capability is rated at 200% In for 1 s or 150% In for 60 s, which helps the drive handle brief torque peaks during operation. Line-side requirements include a rated input current of 46 A, an input voltage range of 380 to 480 V (-15%/+10%) at 50 to 60 Hz, and a three-phase supply. Space-vector PWM and an integrated brake chopper support dynamic deceleration, and output voltage can be regulated from zero up to the incoming phase level. Frequency commands are set with 0.01 Hz digital resolution for fine adjustment.

Apparent power reaches 21.0 kVA, and the default carrier frequency is 6.0 kHz to balance acoustic noise and motor heating. The electronics remain functional from -10 to +40 °C and are housed in an IP 20 frame-size C enclosure that measures 398 mm by 175 mm by 199 mm and weighs 9.0 kg. An LCD panel and onboard potentiometer allow local adjustment, while the Modbus interface connects the drive to higher-level controllers. The unit also includes a Class C3 mains filter for industrial environments, and SVPWM modulation with internal monitoring supports normal drive operation.

Apparent Power
21.0 kVA
Communication Interface
ModBus
Control Hardware
With potentiometer
Default PWM Frequency
6.0 kHz
Depth (T)
199 mm
Design Revision
1
Design Variant
None
Digital Frequency Resolution
0.01 Hz
Display Technology
LCD
Filter Type
Industrial environment, Class C3
Firmware Type
Standard (full version)
Firmware Version
01
Frame Size
C
Height (H)
398 mm
Internal Brake Chopper
Integrated
Modulation Type
SVPWM
Net Weight
9.0 kg
Nominal Voltage
400 V
Operating Temperature
-10 ... +40 °C
Output Frequency
0 ... 400 Hz
Output Power
15.0 kW
Output Voltage
0 V ... mains voltage
Overload Capacity
200% In for 1 s or 150% In for 60 s
Product
Frequency Converter (FVCA)
Protection Rating
IP 20
Rated Input Current
46.0 A
Rated Output Current
33.0 A
Release State
Release number 01
Series Line
01
Speed Range With Encoder
1:1000
Speed Range Without Encoder
1:100
Supply Frequency
50 ... 60 Hz (±5%)
Supply Phases
Three phases
Voltage Range
3 AC 380...480 V (-15 % / +10 %)
Width (B)
175 mm
  • FVCA01115K03P4MDALPNNNN01V01
  • FVCA01 1 15K0 3P4 MDA LP NNNN 01V01
  • fvca01.1-15k0-3p4-mda-lp-nnnn-01v01

Frequently Asked Questions about FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01:

Q: What is the output power rating of the FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01?

A: This frequency converter provides an output power of 15.0 kW.

Q: What communication interface does the FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 support?

A: The Model FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 communicates via ModBus.

Q: What voltage and supply phases does the FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 require?

A: This frequency converter operates at a nominal voltage of 400 V and supports a three-phase supply.

Q: Is there an internal brake chopper on the FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 frequency converter?

A: The integrated internal brake chopper is included in this model.

Q: What type of display technology is used in the FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01?

A: It features an LCD display for user interaction and parameter monitoring.


Internal Product Review

  • ‘‘The FVCA01.1-15K0-3P4-MDA-LP-NNNN-01V01 is a Bosch Rexroth Indramat FVCA frequency converter rated for 15.0 kW output power and 400 V nominal voltage. SVPWM modulation with a default 6.0 kHz PWM frequency supports smooth motor control and stable drive response. An integrated brake chopper and 200% overload capacity for 1 s give this converter excellent headroom for demanding duty cycles.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo